HOUMA, LA —
OSHA Inspection: CAPITAL WELDING & FABRICATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAPITAL WELDING & FABRICATION, INC. in 231 N HOLLYWOOD, HOUMA, LA 70361 (NAICS 332710). OSHA activity number 334614146.
Where did this inspection happen?
- Establishment
- CAPITAL WELDING & FABRICATION, INC.
- Site address
- 231 N HOLLYWOOD
- City
- HOUMA
- State
- LA
- ZIP
- 70361
- Mailing
- 231 N HOLLYWOOD, HOUMA, LA 70361
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 9
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.184 D
- Issued
- Penalty
- Initial $1821.00 · Current $911.00 Reduced
General-duty citation text
29 CFR 1910.184(d): Inspections. Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service. On or about 05/15/2012, the employer did not ensure that all synthethic slings used at the facility were inspected to detect damage. A 1 inch synthetic sling was being used to move sections of pipe in the pipe shop which was severely frayed and cut in numerous locations. This potentially exposes employees to being struck by the pipe should the sling break.
Recent events (2)
- — I (S) $910.5
- — Z (S) $1821
1910.215 A04
- Issued
- Penalty
- Initial $1821.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. On or about 05/15/2012, the employer did not ensure that the spacing of the work rest on the bench grinder located along the back wall of the tube & pipe shop was less than 1/8 inch. The spacing of the work rest from the abrasive wheel was slightly larger than 1/2 inch. This can allow a part or tool to be drawn into the grinder while being held by an employee, injuring the employee.
Recent events (2)
- — I (S) $0
- — Z (S) $1821
1910.253 B05 III B
- Issued
- Penalty
- Initial $1821.00 · Current $911.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(5)(iii)(B): Cylinders shall be handled carefully. Rough handling, knocks, or falls are liable to damage the cylinder, valve or safety devices and cause leakage. On or about 05/15/2012, the employer did not ensure that fuel gas cylinders that were located in the shop were not secured to prevent them from falling over and damaging and/or breaking the valve. This exposed employees to being struck by a projectile should the valve break off. INSTANCES: 1. 2 Argon cylinders were located in the aluminum shop and were unsecured and located in a travelled area 2. An Acetylene cylinder was located near the inner wall of the "Back" shop and was unsecured with forklifts operating in the area.
Recent events (2)
- — I (S) $910.5
- — Z (S) $1821
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2142.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. On or about 05/15/2012, the employer did not ensure that open holes in circuit breaker panels were closed. The large circuit breaker panel located in the tube & pipe shop had openings where circuit breakers were removed and covers had not been installed, exposing employees to live circuits, and to dust/moisture depositing on contacts creating shorting conditions..
Recent events (2)
- — I (S) $1071
- — Z (S) $2142
More inspections at CAPITAL WELDING & FABRICATION, INC.
THIBODAUX, LA—2015-01-07 00:00:00
CAPITAL WELDING & FABRICATION, INC.
HOUMA, LA—1991-12-19 00:00:00
CAPITAL WELDING & FABRICATION INC.
HOUMA, LA—1987-11-09 00:00:00
CAPITAL WELDING & FABRICATION INC.
HOUMA, LA—1987-10-27 00:00:00
CAPITAL WELDING & FABRICATION INC.
View CAPITAL WELDING & FABRICATION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in LA
LAFAYETTE, LA—2026-07-15