Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAPITAL WELDING & FABRICATION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITAL WELDING & FABRICATION, INC. in 231 N HOLLYWOOD, HOUMA, LA 70361 (NAICS 332710). OSHA activity number 334614146.

Watch Capital Welding & Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Capital Welding & Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
231 N HOLLYWOOD
City
HOUMA
State
LA
ZIP
70361
Mailing
231 N HOLLYWOOD, HOUMA, LA 70361
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.184 D

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1821.00 · Current $911.00 Reduced
29 CFR 1910.184(d): Inspections. Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service.    On or about 05/15/2012, the employer did not ensure that all synthethic slings used at the facility were inspected to detect damage. A 1 inch synthetic sling was being used to move sections of pipe in the pipe shop which was severely frayed and cut in numerous locations. This potentially exposes employees to being struck by the pipe should the sling break.
Recent events (2)
  • — I (S) $910.5
  • — Z (S) $1821

1910.215 A04

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1821.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.    On or about 05/15/2012, the employer did not ensure that the spacing of the work rest on the bench grinder located along the back wall of the tube & pipe shop was less than 1/8 inch. The spacing of the work rest from the abrasive wheel was slightly larger than 1/2 inch. This can allow a part or tool to be drawn into the grinder while being held by an employee, injuring the employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1821

1910.253 B05 III B

Serious Gravity 5 3 instances 6 exposed
Issued
Penalty
Initial $1821.00 · Current $911.00 Reduced
29 CFR 1910.253(b)(5)(iii)(B): Cylinders shall be handled carefully. Rough handling, knocks, or falls are liable to damage the cylinder, valve or safety devices and cause leakage.    On or about 05/15/2012, the employer did not ensure that fuel gas cylinders that were located in the shop were not secured to prevent them from falling over and damaging and/or breaking the valve. This exposed employees to being struck by a projectile should the valve break off.    INSTANCES:        1.  2 Argon cylinders were located in the aluminum shop and were unsecured and located in a travelled area        2.  An Acetylene cylinder was located near the inner wall of the "Back" shop and was unsecured with forklifts operating in            the area.
Recent events (2)
  • — I (S) $910.5
  • — Z (S) $1821

1910.305 B01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2142.00 · Current $1071.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.    On or about 05/15/2012, the employer did not ensure that open holes in circuit breaker panels were closed. The large circuit breaker panel located in the tube & pipe shop had openings where circuit breakers were removed and covers had not been installed, exposing employees to live circuits, and to dust/moisture depositing on contacts creating shorting conditions..
Recent events (2)
  • — I (S) $1071
  • — Z (S) $2142

View CAPITAL WELDING & FABRICATION, INC.'s full OSHA safety record →

OXYCHEM

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334614146.