OSHA Inspection: C & C MACHINERY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & C MACHINERY, INC. in 2120 EAST 2ND STREET, RUSSELLVILLE, AR 72801 (NAICS 332710). OSHA activity number 334618931.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & C Machinery, INC. for free Get an email when a new federal OSHA severe-injury report for C & C Machinery, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2120 EAST 2ND STREET
City
RUSSELLVILLE
State
AR
ZIP
72801
Mailing
2120 EAST 2ND STREET, RUSSELLVILLE, AR 72801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
21
Ownership type
Private (A)

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 5 instances 6 exposed
Issued
Oct 12, 2012
Abate by
Oct 23, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    On or about June 6, and at times prior thereto at the establishment employees were exposed to tripping and falling due to passageways not being kept in an orderly condition in the following locations:  a) Northeast corner of old shop along the east wall  b) Northeast corner of old shop along the north wall  c) The area around the press brakes   d) Area between the Bullard VTL and the wall  e) Area behind the Wells-Index vertical mill and the wall
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1200

1910.303 G01

Serious Gravity 1 1 instance 6 exposed
Issued
Oct 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:        On or about June 5, 2012, the failure of this employer to provide and maintain sufficient access and working space about switchboards and panelboards exposed employees to a delay of accessing this electrical current flow equipment should an emergency need occur.     Location: a) Northeast corner of old shop               b) North wall of old shop
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 A03

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 12, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.37(a)(3):     Exit route(s) were not kept free and unobstructed:    On or about June 5, 2012 at the establishment employees were exposed to the hazards of trips, falls and/or delay while exiting the building because objects were partially obstructing the exit route doorway.  Location: Northeast corner of old shop east wall
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1200

1910.212 A01

Serious Gravity 10 9 instances 6 exposed
Issued
Oct 12, 2012
Abate by
Oct 23, 2012
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts.    On or about June 6 and at times prior thereto, operators were exposed to having body parts struck by the unguarded or not adequately guarded rotating chucks of the following lathes:  a) Bullard Vertical Turret Lathe Identity number unknown  b) Bullard Vertical Turret Lathe Identity number 32384  c) Cadillac Lathe Identity number 82055  d) Cadillac Lathe Identity number CL40100G  e) Clausing-Colchester 21" Lathe Identity number 8/0228/05294  f) Yamazaki Lathe Identity number 15744  g) Clausing-Colchester 15" Lathe Identity number 6/0055/25715  h) Lodge & Shipley Lathe Identity number 1087  i) Poreba Lathe Identity number unknown
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2800

1910.212 A03 II

Serious Gravity 10 9 instances 6 exposed
Issued
Oct 12, 2012
Abate by
Oct 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):       On or about June 6, 2012 and at times prior thereto, operators were exposed to having body parts in the danger zone during the operating cycle because the point of operation of the following machinery was not guarded:  a) Ikeda RM 1175 drill press Identity number 81195  b) Bullard vertical turret lathe Identity number 32384  c) Wells-Index vertical milling machine Identity number 18009  d) Wells-Index vertical milling machine Identity number 22674  e) Wells-Index vertical milling machine Identity number 20695   f) Niagara press brake Identity number HD 200-10-12  g) Pacific press brake Identity number unknown  h) Milltronics Partner RH25, Series R vertical milling machine Identity number 6287   i) Miltronics BR 50, Series H vertical milling machine Identity number 10179
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Other-than-serious 1 instance 11 exposed
Issued
Oct 12, 2012
Abate by
Oct 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:      On or about June 5, 2012 at the worksite in the old shop area a flexible cord was supplying 120 volt AC electricity to a permanently mounted overhead lighting device as a substitute for fixed wiring. The cord was in contact with the structural steel which created the possibility of energizing the steel and creating an electric hazard should a person simultaneously contact the steel and a grounded part.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View C & C Machinery, INC.'s full OSHA safety record →