OSHA Inspection: EXTERIOR SOLUTIONS STUCCO & STONE, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EXTERIOR SOLUTIONS STUCCO & STONE, LLC in E. MILL STATION DRIVE, BOISE, ID 83716 (NAICS 238140). OSHA activity number 334619467.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Exterior Solutions Stucco & Stone, LLC for free Get an email when a new federal OSHA severe-injury report for Exterior Solutions Stucco & Stone, LLC is published. One employer, no account, unsubscribe in one click.
Site address
E. MILL STATION DRIVE
City
BOISE
State
ID
ZIP
83716
Mailing
3555 CHILE STREET, BOISE, ID 83705
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 25, 2012
Penalty
Initial $1,156 · Current $750 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a) South, west and north sides of the 1st and 2nd levels; On or about June 6, 2012 and at times prior thereto, employees installing lathe and prepping for stucco were working on 3 foot wide tubular welded frame scaffold that had sections that were not fully planked. Only two planks were used in lieu of the three that were needed.    Note: Abatement certification is Not required for this item.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1156

1926.451 B03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(3)(ii):     The maximum distance from the face for plastering and lathing operations exceeded18 inches (46 cm).    a) South, west and north sides of the 1st and 2nd levels; On or about June 6, 2012 and at times prior thereto, employees installing lathe and prepping for stucco were working on 3 foot wide tubular welded frame scaffold that had sections where the platform ranged up to 28 inches away from the face of the structure.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G04

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4):     Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph.    a) South, west and north sides of the 2nd level; On or about June 6, 2012 and at times prior thereto, employees installing lathe and prepping for stucco were working on 3 foot wide tubular welded frame scaffold that had sections where the top rail or mid rail were missing.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 C02

Other-than-serious 1 instance 3 exposed
Issued
Jul 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    a) South, west and north sides of the 1st level; On or about June 6, 2012 and at times prior thereto, employees installing lathe and prepping for stucco were working on 3 foot wide tubular welded frame scaffold that had inadequate or missing mud sills.     Note: Abatement certification is NOT required for this item.