PITTSFIELD, MA —
OSHA Inspection: CIM'S HOME IMPROVEMENTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CIM'S HOME IMPROVEMENTS in 60 LINDEN STREET, PITTSFIELD, MA 01201 (NAICS 238160). OSHA activity number 334619780.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CIM'S HOME IMPROVEMENTS
- Site address
- 60 LINDEN STREET
- City
- PITTSFIELD
- State
- MA
- ZIP
- 01201
- Mailing
- 45 DANFORTH AVENUE, PITTSFIELD, MA 01201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 3, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: 60 Linden Street, Pittsfield, Massachusetts, roof, three employees, including the foreman, were working on a roof with an eave that was approximately 16 feet from the ground, that were not protected from falls.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B04
- Issued
- Jul 3, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: 60 Linden Street, Pittsfield, Massachusetts, debris dumpster, employees were climbing the unopened, 3 foot, step ladder that was leaning against the dumpster to access the top of the equipment to dump debris buckets.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Jul 3, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: 60 Linden Street, Pittsfield, Massachusetts, roof, employees who were potentially exposed to fall hazards were not provided with training to enable them to recognize the hazards of falling or the procedures to be followed to minimize those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B09
- Issued
- Jul 3, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: 60 Linden Street, Pittsfield, Massachusetts, ladder on front of the building was set up so that the cable television wires went across the top rung of the ladder creating a trip and fall hazard.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B05 I
- Issued
- Jul 3, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). 60 Linden Street, Pittsfield, Massachusetts, ladder on the front of the residence, ladder used to access the roof was erected at an approximate 4 to 3 rise to run ratio in lieu of the required 4 to 1.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jul 3, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 60 Linden Street, Pittsfield, Massachusetts, front of the house, employees were using an extension ladder to gain access to the roof that did not extend at least three feet above the upper landing surface being accessed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Jul 3, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: 60 Linden Street, Pittsfield, MA, employees were not provided training on ladder use that would enable each employee to recognize hazardrs related to ladder use and the procedures to be followed to minimize thes hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334619780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.