DALLAS, TX ·
OSHA Inspection: TD INDUSTRIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TD INDUSTRIES in 6000 DENTON DRIVE, DALLAS, TX 75235 (NAICS 238290). OSHA activity number 334635414.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TD INDUSTRIES
- Site address
- 6000 DENTON DRIVE
- City
- DALLAS
- State
- TX
- ZIP
- 75235
- Mailing
- 13850 DIPLOMAT DRIVE, DALLAS, TX 75234
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 3
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 14, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $6,300 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The employer does not develop, document, and utilize procedures that clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. This violation was discovered on June 04, 2012, where the employer did not develop, document, and utilize procedures that clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy when employees serviced and maintained equipment and machinery.
Recent events (3)
- · F (O) $4000
- · C (S) $6300
- · Z (S) $6300
1910.212 A01
- Issued
- Nov 14, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer does not ensure that one or more methods of machine guarding is provided to protect the operator and other employees in the machine area from hazards such as those created by point-of-operation, ingoing nip points, rotating parts, flying chips and sparks. This violation was discovered on June 6, 2012, in the maintenance shop; where employees operated a Delta drill press that did not have a shield and chuck guard.
Recent events (3)
- · F (O) $2250
- · C (S) $4500
- · Z (S) $4500
1910.215 B09
- Issued
- Nov 14, 2012
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: The employer does not ensure that the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top does not exceed one-fourth inch. This violation occurred on June 06, 2012, in the maintenance shop; where at least two (2) employees used a bench grinder that did not have the adjustable tongue guard in use and adjusted to one-fourth inch of the wheel periphery.
Recent events (3)
- · F (O) $2250
- · C (S) $4500
- · Z (S) $4500
1910.253 B04 III
- Issued
- Nov 14, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour: The employer does not ensure that oxygen cylinders in storage are separated from fuel-gas cylinders or combustible materials, a minimum distance of 20-feet or by a noncombustible barrier at least 5-feet high having a fire-resistance rating of at least one-half hour. This violation occurred on June 06, 2012, in the maintenance shop; where full tanks of oxygen, acetylene, and argon were stored together.
Recent events (3)
- · F (S) $0
- · C (S) $4500
- · Z (S) $4500
More inspections at TD Industries
View TD Industries's full OSHA safety record →
More inspections in this industry (NAICS 238290)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334635414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.