OSHA Inspection: TD INDUSTRIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TD INDUSTRIES in 6000 DENTON DRIVE, DALLAS, TX 75235 (NAICS 238290). OSHA activity number 334635414.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TD Industries for free Get an email when a new federal OSHA severe-injury report for TD Industries is published. One employer, no account, unsubscribe in one click.
Establishment
TD INDUSTRIES
Site address
6000 DENTON DRIVE
City
DALLAS
State
TX
ZIP
75235
Mailing
13850 DIPLOMAT DRIVE, DALLAS, TX 75234
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
3
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 10 instances 3 exposed
Issued
Nov 14, 2012
Abate by
Dec 6, 2012
Penalty
Initial $6,300 · Current $4,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     The employer does not develop, document, and utilize procedures that clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy.  This violation was discovered on June 04, 2012, where the employer did not develop, document, and utilize procedures that clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy when employees serviced and maintained equipment and machinery.
Recent events (3)
  • · F (O) $4000
  • · C (S) $6300
  • · Z (S) $6300

1910.212 A01

Other-than-serious 1 instance 1 exposed
Issued
Nov 14, 2012
Abate by
Nov 19, 2012
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    The employer does not ensure that one or more methods of machine guarding is provided to protect the operator and other employees in the machine area from hazards such as those created by point-of-operation, ingoing nip points, rotating parts, flying chips and sparks.  This violation was discovered on June 6, 2012, in the maintenance shop; where employees operated a Delta drill press that did not have a shield and chuck guard.
Recent events (3)
  • · F (O) $2250
  • · C (S) $4500
  • · Z (S) $4500

1910.215 B09

Other-than-serious 1 instance 2 exposed
Issued
Nov 14, 2012
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch:    The employer does not ensure that the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top does not exceed one-fourth inch.  This violation occurred on June 06, 2012, in the maintenance shop; where at least two (2) employees used a bench grinder that did not have the adjustable tongue guard in use and adjusted to one-fourth inch of the wheel periphery.
Recent events (3)
  • · F (O) $2250
  • · C (S) $4500
  • · Z (S) $4500

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2012
Abate by
Nov 19, 2012
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet  high having a fire-resistance rating of at least one-half hour:                                                                                                                      The employer does not ensure that oxygen cylinders in storage are separated from fuel-gas cylinders or combustible materials, a minimum distance of 20-feet or by a noncombustible barrier at least 5-feet high having a fire-resistance rating of at least one-half hour.  This violation occurred on June 06, 2012, in the maintenance shop; where full tanks of oxygen, acetylene, and argon were stored together.
Recent events (3)
  • · F (S) $0
  • · C (S) $4500
  • · Z (S) $4500

View TD Industries's full OSHA safety record →