WASHINGTON, DC —
OSHA Inspection: BUILT UP ROOFING SYSTEMS, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BUILT UP ROOFING SYSTEMS, INC in 3506 GEORGIA AVE, NW, WASHINGTON, DC 20009 (NAICS 238160). OSHA activity number 334640182.
Where did this inspection happen?
- Establishment
- BUILT UP ROOFING SYSTEMS, INC
- Site address
- 3506 GEORGIA AVE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 3711 WELLS AVE, MOUNT RAINIER, MD 20712
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 B01
- Issued
- Penalty
- Initial $2310.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Trash Room Roof, West Side of the Building - An extension ladder did not extend 3' past the landing. A foreman and roofers were observed using a ladder which only extended 30" past the top of the parapet wall exposing them to a 16 fall hazard.
Recent events (3)
- — F (S) $1600
- — C (S) $2310
- — Z (S) $2310
1926.501 B10
- Issued
- Penalty
- Initial $15400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety net s a) Trash Room Roof, West Side of the Building - A foreman and roofers were observed without fall protection while on the roof exposing them to a 16 fall hazard. Built Up Roofing Systems was previously cited for a violation of this occupational safety and health standard, or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA Inspection # 312807399, Citation # 1, Item # 1, and was affirmed on 04/23/09, with respect to a workplace located at 3819 Jay Street, Bldg. 17, NE, Washington, DC 20019.
Recent events (3)
- — F (R) $0
- — C (R) $15400
- — Z (R) $15400
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334640182.