ROSCOE, IL —
OSHA Inspection: CUSTOM CONSTRUCTION SYSTEMS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CUSTOM CONSTRUCTION SYSTEMS LLC in 10816 MAIN ST., ROSCOE, IL 61073 (NAICS 238160). OSHA activity number 334644002.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM CONSTRUCTION SYSTEMS LLC
- Site address
- 10816 MAIN ST.
- City
- ROSCOE
- State
- IL
- ZIP
- 61073
- Mailing
- 13840 BRIARWOOD LANE, ROSCOE, IL 61073
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Jun 28, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A metal frame scaffold system from which employees were working approximately 12 feet above grade was not fully planked. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01
- Issued
- Jun 28, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Employee working from a metal frame scaffold system approximately 12 feet above grade was not utilizing fall protection. There is no abatement certification or documemntation required for this item
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.501 B11
- Issued
- Jun 28, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: Employees working on a steep 7 in 12 commercial roof ranging from 12 to 13.5 above grade were not utilizing any method of fall protection. There is no abatement certification or documentation required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at Custom Construction Systems LLC
View Custom Construction Systems LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334644002.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.