Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: BRINKMAN PRECISION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRINKMAN PRECISION, INC. in 100 PARK CENTRE DRIVE, WEST HENRIETTA, NY 14586 (NAICS 336413). OSHA activity number 334654787.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brinkman Precision, INC. for free Get an email when a new federal OSHA severe-injury report for Brinkman Precision, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 PARK CENTRE DRIVE
City
WEST HENRIETTA
State
NY
ZIP
14586
Mailing
100 PARK CENTRE DRIVE, WEST HENRIETTA, NY 14586
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
87
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 29, 2012
Penalty
Initial $3,000 · Current $2,000 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) On or about 6/12/21 in the Maint. shop area: the unused portion of the Behringer brand horizontial band saw, type HBP260A, machine number 11961021 was not guarded.     Abatement Certification
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3000

1910.333 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2012
Abate by
Jul 29, 2012
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.333(a)(2):     "Energized parts." If the exposed live parts are not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices shall be used to protect employees who may be exposed to the electrical hazards involved. Such work practices shall protect employees against contact with energized circuit parts directly with any part of their body or indirectly through some other conductive object. The work practices that are used shall be suitable for the conditions under which the work is to be performed and for the voltage level of the exposed electric conductors or circuit parts. Specific work practice requirements are detailed in paragraph (c) of this section.    a) On or about 6/12/12 in the manufacturing area; while disconnecting the plug connector on the ballasts of on an energized overhead fluorescent light fixture ( 277 volts single phase ) employee was wearing a polyester work uniform, metal framed safety glasses and metal jewelry.       b) On or about 6/12/12 in the manufacturing area; employees are exposed to energized electrical parts during voltage testing of 240/480 volts AC without the use of specific work practices.       Abatement Documentation
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2012
Abate by
Jul 29, 2012
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i):     Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.   Note: Personal protective equipment requirements are contained in subpart I of this part.    a) On or about 6/12/12 in the shop area; during the removal of an overhead fluorescent light fixture, with the circuit energized ( 277 volts AC ) when the plug connector on the ballast was pulled apart, the power conductor contacted the metal portion of the light fixture and grounded out resulting in a 1/2" hole in the metal.  No electrical protective equipment was being used while performing this activity.      b) ) On or about 6/12/12 in the manufacturing area; employees are exposed to energized electrical parts during voltage testing of 240/480 volts AC without the use of proper protective clothing.      Abatement Documentation
Recent events (2)
  • · I (S) $0
  • · Z (S) $5000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334654787.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.