ALBANY, NY —
OSHA Inspection: PARSONS CHILD AND FAMILY CENTER
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PARSONS CHILD AND FAMILY CENTER in 60 ACADEMY ROAD, ALBANY, NY 12208 (NAICS 624110). OSHA activity number 334660222.
Where did this inspection happen?
- Establishment
- PARSONS CHILD AND FAMILY CENTER
- Site address
- 60 ACADEMY ROAD
- City
- ALBANY
- State
- NY
- ZIP
- 12208
- Mailing
- 60 ACADEMY ROAD, ALBANY, NY 12208
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 624110
- Employees
- 625
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1913.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. a) Maintenance shop- On or about 06/12/12- Amerex ABC fire extinguisher located near the entrance door was not identified with a location label. b) Maintenance shop- On or about 06/12/12- A type fire extinguisher located in the rear of the shop was not identified with a location label. c) School building- On or about 06/12/12- Amerex ABC fire extinguisher was unmounted and used as a door prop.
Recent events (2)
- — I (S) $1912.5
- — Z (S) $2550
1910.213 C01
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $2550.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Maintenance shop- on or about- On and before 06/12/12- Powermatic table saw was not equipped with an adjusting hood exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $2550
- — Z (S) $3400
1910.213 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Building and Grounds Maintenance Shop- On and before 6/12;/12- Powermatic table saw was not equipped with a spreader exposing employees to struck-by hazards when cutting treated 3/4" plywood. NOTE: The spreader in connection with groving, dodoing or rabbeting is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) Maintenance shop- on or about- On and before 06/12/12- Powermatic table saw was not equipped with an nono kickback fingers exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.4 A
- Issued
- Penalty
- Initial $700.00 · Current $525.00 Reduced
General-duty citation text
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a) Facility- On or about 6/12/12- An employee on 05/31/12 fell down a flight of steps and was injured and within six days of the injury the employer failed to record the injury oin their OSHA 300 log.
Recent events (2)
- — I (O) $525
- — Z (O) $700
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Building and Grounds Maintenance Shop- on and before 6/12/12- Employer failed to supply employees voluntarily using N-95 respirators with Appendix D of the standard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PARSONS CHILD AND FAMILY CENTER
ALBANY, NY—2013-01-09 00:00:00
PARSONS CHILD AND FAMILY CENTER
View PARSONS CHILD AND FAMILY CENTER's full OSHA safety record →
More inspections in this industry (NAICS 624110)
SARASOTA, FL—2026-05-14
THE FLORIDA CENTER FOR EARLY CHILDHOOD, INC
RICHMOND, CA—2026-05-12
WEST CONTRA COSTA YOUTH SERVICE BUREAU
MONTICELLO, NY—2026-05-05
THE CENTER FOR DISCOVERY
DORCHESTER, MA—2026-04-17
MASSACHUSETTS DEPARTMENT OF YOUTH SERVICES
INDEPENDENCE, VA—2026-04-14
ROOFTOP OF VIRGINIA CAP
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334660222.