SWINK, CO ·
OSHA Inspection: SHOWALTER INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHOWALTER INC. in 501 WILEY, SWINK, CO 81077 (NAICS 424510). OSHA activity number 334665791.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHOWALTER INC.
- Site address
- 501 WILEY
- City
- SWINK
- State
- CO
- ZIP
- 81077
- Mailing
- P.O. BOX 265, SWINK, CO 81077
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.303 B01 II
- Issued
- Aug 16, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) On or about May 4, 2012 and at times prior, Showalter Inc. did not ensure that employees were protected from electrical hazards. The electrical switches and breakers were installed in cabinets made of wood. The wood is not rated to be adequate protection for these electrical components.
Recent events (2)
- · I (S) $850
- · Z (S) $1700
1910.303 B08 I
- Issued
- Aug 16, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was to be mounted: a) On or about May 4, 2012 and at times prior, Showalter Inc did not ensure that employees were protected from electrical hazards. A J-box at the drying unit was not secured.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 D
- Issued
- Aug 16, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(d): Arcing parts. Parts of electric equipment that in ordinary operation produce arcs, sparks, flames, or molten metal were not enclosed or separated and isolated from all combustible material. a) On or about May 4, 2012 and at times prior, Showalter Inc. did not ensure that employees were protected from electrical hazards. Combustable items such as gear oil, rags, and plastic feed bags were stored inside the wooden boxes which housed the switches and breakers for the receiving pit area.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV B
- Issued
- Aug 16, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) On or about May 4, 2012 and at times prior, Showalter Inc. did not ensure that employees were protected from electrical hazards. Flexible cords were run through the plywood walls of the switches and breakers box.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 II
- Issued
- Aug 16, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced: a) On or about May 4, 2012 and at times prior, Showalter Inc. did not ensure that employees were protected from electrical hazards. The tape used on the outside of the splice was not rated for use in wet and damp locations. Wrapping it around the cord did not bring the outer insulation of the cord to manufacturers specifications.