Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OPPORTUNITY VILLAGE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OPPORTUNITY VILLAGE in NELLIS AFB, RED HORSE DFAC-BUILDING 10206 AREA II, NELLIS AFB, LAS VEGAS, NV 89191 (NAICS 722212). OSHA activity number 334671989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Opportunity Village — free Get an email when a new federal OSHA severe-injury report for Opportunity Village is published. One employer, no account, unsubscribe in one click.
Establishment
OPPORTUNITY VILLAGE
Site address
NELLIS AFB, RED HORSE DFAC-BUILDING 10206 AREA II, NELLIS AFB
City
LAS VEGAS
State
NV
ZIP
89191
Mailing
6300 W. OAKEY BLVD, LAS VEGAS, NV 89146
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722212
Employees
7
Ownership type
A

9 citations on file for this inspection.

1903.2 A01

Other-than-serious 1 instance 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,100 · Current $500 Reduced
29 CFR 1903.2(a)(1): The employer did not post and keep posted OSHA notices informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards.:  a) At the Red Horse Dining establishment, there was no OSHA Poster posted by the employer in a conspicuous place where notices to employees are customarily posted.
Recent events (3)
  • — F (O) $500
  • — C (S) $2100
  • — Z (S) $2100

1910.23 A08

Other-than-serious 1 instance 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  a) At the Red Horse dining facility, in the entrance hallway there was a 2' inch by 4' inch floor hole.
Recent events (3)
  • — F (O) $1050
  • — C (S) $2100
  • — Z (S) $2100

1910.36 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 26, 2012
Abate by
Nov 6, 2012
Penalty
Initial $3,500 · Current $2,500 Reduced
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.  a) In the main entry hallway, the walk-in freezer had a door that could not be opened from the inside.
Recent events (3)
  • — F (S) $2500
  • — C (S) $3500
  • — Z (S) $3500

1910.141 A04 II

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.141(a)(4)(ii): All sweepings, solid or liquid wastes, refuse, and garbage were not removed in such a manner as to avoid creating a menace to health and as often as necessary or appropriate to maintain the place of employment in a sanitary condition.    a) At the Red Horse dining facility, in the conjoining room between the dish pan wash room and kitchen, the floor had visable left over food sweepings and a medium sized mouse trap had a decomposing mouse and food matter.
Recent events (3)
  • — F (S) $0
  • — C (S) $4000
  • — Z (S) $4000

1910.157 C01

Serious Gravity 1 1 instance 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,100 · Current $2,800
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting employees to injuries:  a) At the Red Horse Dining Facility, Building 10206, kitchen door entrance, there was a fire extinguisher sitting on the floor.
Recent events (3)
  • — F (S) $2800
  • — C (S) $2100
  • — Z (S) $2100

1910.157 E02

Serious Gravity 1 5 instances 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a) At the Area II, Red Horse Dining Facility, Building 10206, inspection tags attached to five (5) Fire extinguishers had not been annotated as visually inspected since Jun 2011.
Recent events (3)
  • — F (S) $0
  • — C (S) $2100
  • — Z (S) $2100

1910.303 B07 IV

Deleted Serious Gravity 5 2 instances 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:    a) At the Red Horse Dining Facility, including but not limited to the kithchen area entrance, a duplex convenience switch was partially broken off and receding into faceplate exposing employer to live parts.    b) In the storeroom, by the refridgerator a 220 live black electrical cable with bare exposed wires was hanging down 61/2 feet from the floor
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.303 F02

Deleted Serious Gravity 1 4 instances 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) At the Area II, Red Horse Dining Facility, Building 10206, electrical panel boxes inncluding but not limited to the kitchen and entrance hallway, did not have switches legibly marked to indicate purpose.
Recent events (3)
  • — F (S) $0
  • — C (S) $2100
  • — Z (S) $2100

1910.305 B01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 26, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,800 · Current $3,800
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were causing abrasions to conductors and not effectively closed:    a) At the Red Horse Dining facility, in the spice supply office, there were exposed 110 volt electrical wires as a result of damaged conduit pipe separated from side of electrical panel box cut out.    b) In the storeroom, by the refridgerator a 220 live black electrical cable with bare exposed wires was hanging down 61/2 feet from the floor
Recent events (3)
  • — F (S) $3800
  • — C (S) $2800
  • — Z (S) $2800

View Opportunity Village's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334671989.