NELLIS AFB, NV ·
OSHA Inspection: NELLIS AIR FORCE BASE, GUN CLUB
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NELLIS AIR FORCE BASE, GUN CLUB in GUN CLUB, BUILDING 10095, NELLIS AFB, NV 89191 (NAICS 928110). OSHA activity number 334673605.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NELLIS AIR FORCE BASE, GUN CLUB
- Site address
- GUN CLUB, BUILDING 10095
- City
- NELLIS AFB
- State
- NV
- ZIP
- 89191
- Mailing
- HEADQUARTERS 99TH AIR BASE WING (ACC) BUILDING 7, NELLIS AFB, NV 89191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 3
- Ownership type
- Federal government (D)
Citations
11 citations on file for this inspection.
1910.22 A03
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(3): To facilitate cleaning, every floor, working place, and passageway shall be kept free from protruding nails, splinters, holes, or loose boards. a) At the Gun Club maintenance shop, in front of the floor mounted bench grinder there was a one half inch diameter bolt protruding from the floor three (3) inches. The protruding bolt constitutes a trip and fall hazard.
Recent events (1)
- · Z (S) $0
1910.37 A03
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Stairs or a ramp were not provided where the exit route was not substantially level. a) At the access door to the Gun Club maintenance shop, the step down was seventeen inch.
Recent events (1)
- · Z (S) $0
1910.106 E09 III
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) At the maintenance shop a metal refuse receptacle used for combustible oily rags disposal was full with oily rags and other trash and the damaged metal lid hinge would not allow lid to close completely.
Recent events (1)
- · Z (S) $0
1910.215 A04
- Issued
- Oct 26, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) At the maintenance shop, the work rest for a Craftsman 1/2 horse power bench grinder mounted on a shop made metal stand, was adjusted to one fourth (1/4) inch.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Oct 26, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) At the maintenance shop, the Craftsman bench grinder mounted on a shop made metal stand: the distance between the tongue guard and abrasive wheel was one inch.
Recent events (1)
- · Z (S) $0
1910.215 D01
- Issued
- Oct 26, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(d)(1): Immediately before mounting, all wheels were not closely inspected and sounded by the user (ring test) to make sure they have not been damaged in transit, storage, or otherwise. The spindle speed of the machine was not checked before mounting of the wheel to be certain that it did not exceed the maximum operating speed marked on the wheel. Wheels should be tapped gently with a light nonmetallic implement, such as the handle of a screwdriver for light wheels, or a wooden mallet for heavier wheels. If they sound cracked (dead), they shall not be used. a) At the maintenance shop, a Craftsman 1/2 horse power bench grinder mounted on a shop made metal stand, did not have a ring test performed and spindle speed of the machine was not checked before mounting the wheel.
Recent events (1)
- · Z (S) $0
1910.303 B07 IV
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating; a) At the maintenance shop, on the work and test bench wall there was a duplex 120 volt receptacle with the lower ground plug-in partially broken off.
Recent events (1)
- · Z (S) $0
1910.303 C03 I
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a) At the maintenance shop, a "Central Machinery" under hung hoist; model 44006, hoist controller cord was spliced with electrical tape at the hoist box and at pendant.
Recent events (1)
- · Z (S) $0
1910.305 A02 IX
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard a) At the maintenance shop, three ceiling mounted illumination lamps did not have lamp holders with guards to prevent breakage.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) At the maintenance shop, a white extension cord eight (8) feet long was used to power the under hung hoist, Model 44006.
Recent events (1)
- · Z (S) $0
1910.334 C02
- Issued
- Oct 26, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(c)(2): Test instruments and equipment and all associated test leads, cables, power cords, probes, and connectors were not visually inspected for external defects and damage before the electric equipment was used: a) At the maintenance shop, on the wall above test bench a trap and skeet pendent tester was mounted that had a mating cord with missing and severely deteriated outer sheathing.
Recent events (1)
- · Z (S) $0
More inspections at Nellis AIR Force Base, GUN Club
View Nellis AIR Force Base, GUN Club's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334673605.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.