Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: U.S. AIR FORCE - ANDERSEN, 36TH CIVIL ENGINEERING SQUADRON (CES), UNIT 14007

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. AIR FORCE - ANDERSEN, 36TH CIVIL ENGINEERING SQUADRON (CES), UNIT 14007 in BLDG. 22007, HVAC ARC LIGHT BLVD., ANDERSEN AFB, YIGO, GU 96929 (NAICS 928110). OSHA activity number 334676400.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force - Andersen, 36TH Civil Engineering Squadron (CES), Unit 14007 for free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force - Andersen, 36TH Civil Engineering Squadron (CES), Unit 14007 is published. One employer, no account, unsubscribe in one click.
Site address
BLDG. 22007, HVAC ARC LIGHT BLVD., ANDERSEN AFB
City
YIGO
State
GU
ZIP
96929
Mailing
NAVFAC MARIANAS PSC 455, BOX 195, FPO AP, PITI, GU 96915
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
130
Ownership type
Federal government (D)

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 8, 2012
Abate by
Dec 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    Mezzanine:  On or about 6/12/2012, and at times prior thereto, the following were found to be inadequate:    1.  The top rail measured 36 inches; 42 inches is required  2.  There was no mid-rail; mid-rail should be placed approximately half-way between the top rail and floor.  3.  The toe board measured 1.5 inches from floor; 4 inches is required
Recent events (1)
  • · Z (S) $0

1910.23 E03 IV

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 8, 2012
Abate by
Dec 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types shall be of such construction that the completed structure shall be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail.    Mezzanine: On or about 6/12/2012, and at times prior thereto, the top rail was not mounted securely.
Recent events (1)
  • · Z (S) $0

1910.36 D03

Serious Gravity 5 4 instances 2 exposed
Issued
Nov 8, 2012
Abate by
Nov 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(3): An exit route door may be locked from the inside only in mental, penal, or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to remove occupants from the facility during an emergency.    Pest Control, mixing room, insecticide storage room - On or about 6/11/12, and at times prior thereto, designated exits doors were locked.
Recent events (1)
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 22 exposed
Issued
Nov 8, 2012
Abate by
Dec 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Bldg. 20021, Grounds Shop - On or about 6/18/12, and at times prior thereto, a Jet drill press, MD. JIP-15MF, SN. 5010097 did not have a guard at the point of operation.    (b) Power Production - On or about 6/12/12, and at times prior thereto, a Sears 15" drill press, SN# 9710800106, did not have a guard at the point of operation.
Recent events (1)
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Nov 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.    Power Producition - On or about 6/12/12, and at times prior thereto, the interior cover of the circuit breaker (120 V) for the bay lights/ice maker had numerous openings thereby exposing live electrical parts.
Recent events (1)
  • · Z (S) $0

View U.S. AIR Force - Andersen, 36TH Civil Engineering Squadron (CES), Unit 14007's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334676400.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.