YIGO, GU ·
OSHA Inspection: U.S. AIR FORCE - ANDERSEN, 36TH CIVIL ENGINEERING SQUADRON (CES), UNIT 14007
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. AIR FORCE - ANDERSEN, 36TH CIVIL ENGINEERING SQUADRON (CES), UNIT 14007 in BLDG. 22007, HVAC ARC LIGHT BLVD., ANDERSEN AFB, YIGO, GU 96929 (NAICS 928110). OSHA activity number 334676400.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- BLDG. 22007, HVAC ARC LIGHT BLVD., ANDERSEN AFB
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- NAVFAC MARIANAS PSC 455, BOX 195, FPO AP, PITI, GU 96915
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 130
- Ownership type
- Federal government (D)
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Nov 8, 2012
- Abate by
- Dec 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Mezzanine: On or about 6/12/2012, and at times prior thereto, the following were found to be inadequate: 1. The top rail measured 36 inches; 42 inches is required 2. There was no mid-rail; mid-rail should be placed approximately half-way between the top rail and floor. 3. The toe board measured 1.5 inches from floor; 4 inches is required
Recent events (1)
- · Z (S) $0
1910.23 E03 IV
- Issued
- Nov 8, 2012
- Abate by
- Dec 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types shall be of such construction that the completed structure shall be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail. Mezzanine: On or about 6/12/2012, and at times prior thereto, the top rail was not mounted securely.
Recent events (1)
- · Z (S) $0
1910.36 D03
- Issued
- Nov 8, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(3): An exit route door may be locked from the inside only in mental, penal, or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to remove occupants from the facility during an emergency. Pest Control, mixing room, insecticide storage room - On or about 6/11/12, and at times prior thereto, designated exits doors were locked.
Recent events (1)
- · Z (S) $0
1910.212 A01
- Issued
- Nov 8, 2012
- Abate by
- Dec 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Bldg. 20021, Grounds Shop - On or about 6/18/12, and at times prior thereto, a Jet drill press, MD. JIP-15MF, SN. 5010097 did not have a guard at the point of operation. (b) Power Production - On or about 6/12/12, and at times prior thereto, a Sears 15" drill press, SN# 9710800106, did not have a guard at the point of operation.
Recent events (1)
- · Z (S) $0
1910.305 B01 II
- Issued
- Nov 8, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. Power Producition - On or about 6/12/12, and at times prior thereto, the interior cover of the circuit breaker (120 V) for the bay lights/ice maker had numerous openings thereby exposing live electrical parts.
Recent events (1)
- · Z (S) $0
More inspections at U.S. AIR Force - Andersen, 36TH Civil Engineering Squadron (CES), Unit 14007
More inspections in this industry (NAICS 928110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334676400.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.