At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, MT. RAINIER, OHANAPECOSH MAINTENANCE in HWY 123, PACKWOOD, WA 98361 (NAICS 712190). OSHA activity number 334681004.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- HWY 123
- City
- PACKWOOD
- State
- WA
- ZIP
- 98361
- Mailing
- 55210 238TH AVE EAST, ASHFORD, WA 98304
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 300
- Ownership type
- Federal government (D)
Citations
15 citations on file for this inspection.
1910.23 C
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a) Carpenter Shop, where the ladder way located adjacent to the overhead storage stairway was not equipped with guard railing exposing employees to a six foot fall.
Recent events (1)
- · Z (S) $0
1910.179 B05
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29CFR 1910.179(b)(5): The rated load of the crane was not plainly marked on each side of the crane: a) Carpenter Shop, where the beam supporting the overhead under hung crane was not marked with a load rating.
Recent events (1)
- · Z (S) $0
1910.212 B
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Carpenter Shop, where the Delta drill press was not anchored.
Recent events (1)
- · Z (S) $0
1910.242 A
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a) Carpenter Shop, where the feed roller clutch handle on the Power Matic Planer, #G-6678, was held in the in position with a bungee cord that was wrapped around the adjacent column.
Recent events (1)
- · Z (S) $0
1910.303 G02 I D
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by elevation of 2.44 m (8.0 ft) or more above the floor or other working surface: a) Fire Cache Loft, where the florescent light fixtures equipped with unguarded bulbs were located 81 ? inches above floor level.
Recent events (1)
- · Z (S) $0
1910.22 D01
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related: a) Carpenter Shop, where the storage space located above the parts storage room was not equipped with a load rating plate. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309098242, citation no. 3, item no. 1, issued on September 08, 2010 with respect to a workplace at Stehekin, WA. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094316, citation no. 2, item no. 1, issued on October 3, 2008 with respect to a workplace at Port Angeles, WA.
Recent events (1)
- · Z (R) $0
1910.215 A04
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Carpenter Shop, where the work rest on the Jet bench grinder measured ? inch from the abrasive wheel. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309098242, citation no. 2, item no. 1, issued on September 08, 2010 with respect to a workplace at Stehekin, WA. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094282, citation no. 1, item no.12, issued on September 23, 2008 with respect to a workplace at Forks, WA.
Recent events (1)
- · Z (R) $0
1910.215 B09
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Carpenter Shop, where the tongue guard on the Jet bench grinder measured 1/4 inch from the abrasive wheel. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309098242, citation no. 2, item no. 2, issued on September 08, 2010 with respect to a workplace at Stehekin, WA. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094316, citation no. 2, item no. 2, issued on October 3, 2008 with respect to a workplace at Port Angeles, WA.
Recent events (1)
- · Z (R) $0
1910.303 G01 II
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage: a) Carpenter Shop, where items including orange poles and a Sanyo microwave oven were stored in front of circuit panel B. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096154, citation no. 1, item no. 2, issued on September 9, 2009 with respect to a workplace at Marblemount, WA. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094308, citation no. 3, item no. 2, issued on October 3, 2008 with respect to a workplace at Forks, WA. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094282, citation no. 2, item no. 1, issued on September 23, 2008 with respect to a workplace at Forks, WA.
Recent events (1)
- · Z (R) $0
1910.305 J01 I
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29CFR1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals: a) Maintenance Building, where the light fixture in the janitorial closet was equipped with an unguarded single bulb located 88 inches above floor level. The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096154, citation no. 1, item no. 3, issued on September 9, 2009 with respect to a workplace at Marblemount, WA.
Recent events (1)
- · Z (R) $0
1910.23 E01
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29CFR 1910.23(e)(1): Standard railing did not consist of top rail, intermediate rail, and posts: a) Maintenance Building, where the railing on the stairway located in the Break Room was not equipped with midrails.
Recent events (1)
- · Z (O) $0
1910.37 B02
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Maintenance Building, where designated emergency exit doors were not equipped with exit signs.
Recent events (1)
- · Z (O) $0
1910.157 C01
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29CFR1910.157(c)(1): Fire extinguishers were not mounted, located and identified so that they were readily accessible to employees without subjecting the employees to possible injury: a) Maintenance Building, where employees would be expected to fight incipient stage fires, fire extinguishers not readily accessible were not identified.
Recent events (1)
- · Z (O) $0
1910.157 E02
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Maintenance Building, where employees would be expected to fight incipient stage fires, fire extinguishers were not inspected on a monthly basis.
Recent events (1)
- · Z (O) $0
1910.157 E03
- Issued
- Jul 16, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Maintenance Building, where employees would be expected to fight incipient stage fires, fire extinguishers were not inspected annually.
Recent events (1)
- · Z (O) $0
More inspections at National Park Service, MT. Rainier, Ohanapecosh Maintenance
View National Park Service, MT. Rainier, Ohanapecosh Maintenance's full OSHA safety record →
More inspections in this industry (NAICS 712190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334681004.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.