Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SANTA FE BALLROOM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SANTA FE BALLROOM in 13201 CF HAWN FREEWAY, DALLAS, TX 75253 (NAICS 238110). OSHA activity number 334685781.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Santa FE Ballroom for free Get an email when a new federal OSHA severe-injury report for Santa FE Ballroom is published. One employer, no account, unsubscribe in one click.
Establishment
SANTA FE BALLROOM
Site address
13201 CF HAWN FREEWAY
City
DALLAS
State
TX
ZIP
75253
Mailing
13201 CF HAWN FREEWAY, DALLAS, TX 75253
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
4
Ownership type
Local government (B)

5 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,800 · Current $840 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary:    On 06/12/2012, at an establishment located at 13201 C.F. Hawn Freeway, Dallas, Texas; at the front of the building, employees working from a tubular welded frame scaffold when plastering a wall were exposed to a fall hazard. The working platforms were not fully planked and consisted of two planks each.
Recent events (2)
  • · I (S) $840
  • · Z (S) $2800

1926.451 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,000 · Current $600 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:    On 06/12/2012, at an establishment located at 13201 C.F. Hawn Freeway, Dallas, Texas; at the front of the building, on a three-tier tubular welded frame scaffold, employees climbing scaffold end frames were exposed to a fall hazard.
Recent events (2)
  • · I (S) $600
  • · Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,800 · Current $840 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:    On 06/12/2012, at an establishment located at 13201 C.F. Hawn Freeway, Dallas, Texas; at the front of the building, employees working from a tubular welded frame scaffold when plastering a wall were exposed to a fall hazard. The scaffold was not provided with guardrails and the employees did not wear personal fall protection.
Recent events (2)
  • · I (S) $840
  • · Z (S) $2800

1926.451 F07

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,600 · Current $480 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:    On 06/12/2012, at an establishment located at 13201 C.F. Hawn Freeway, Dallas, Texas; at the front of the building, an 8 x 3 tier tubular welded frame scaffold was not erected under the supervision of a competent person.
Recent events (2)
  • · I (S) $480
  • · Z (S) $1600

1926.452 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(2): All brace connections were not secured:    On 06/12/2012, at an establishment located at 13201 C.F. Hawn Freeway, Dallas, Texas; at the front of the building, employees plastering a wall worked from an 8 X 3 tier tubular welded frame scaffold that not leveled and square.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334685781.