BROCKTON, MA —
OSHA Inspection: NORWOOD MOTOR PARTS COMPANY, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORWOOD MOTOR PARTS COMPANY, INCORPORATED in 43 NORTH MONTELLO STREET, BROCKTON, MA 02305 (NAICS 423120). OSHA activity number 334686003.
Where did this inspection happen?
- Establishment
- NORWOOD MOTOR PARTS COMPANY, INCORPORATED
- Site address
- 43 NORTH MONTELLO STREET
- City
- BROCKTON
- State
- MA
- ZIP
- 02305
- Mailing
- 43 NORTH MONTELLO STREET, BROCKTON, MA 02303
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- Employees
- 37
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 A01
- Issued
- Sep 11, 2012
- Abate by
- Dec 15, 2012
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.23(a)(1): Stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section. The railing shall be provided on all exposed sides (except at entrance to stairway). First floor: A standard railling was not provided at first floor stairway landing. The top rail measured 29 inches from floor level. Note: Standard railing shall consist of top rail, intermediate rail and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor level.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.37 B02
- Issued
- Sep 11, 2012
- Penalty
- Initial $1,517 · Current $1,062 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a. First Floor: There was no exit sign for side door leading out to North Montello Street. b. Basement: There was no exit sign for door leading out of basement.
Recent events (2)
- — I (S) $1062
- — Z (S) $1517
1910.212 A01
- Issued
- Sep 11, 2012
- Abate by
- Oct 24, 2012
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: a. First Floor, Conveyor: The in running nip point where the belt moves over the roller was not fully guarded. b. Second Floor Conveyor: The in running nip point where the belt moves over the roller was not fully guarded.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.305 B01 II
- Issued
- Sep 11, 2012
- Penalty
- Initial $2,023 · Current $1,416 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. First floor: An electrical box at conveyor was missing a knock-out cover. b. Third Floor: An electrical box in the break room, was missing a knock-out cover. c. Third Floor: Electrical boxes were missing covers for four knock-outs. d. Fourth Floor: An electricall box at conveyor was missing a knock-out cover. e. Third Floor: Panel box, openings at bottom of circuit breakers were not covered.
Recent events (2)
- — I (S) $1416
- — Z (S) $2023
1910.157 C01
- Issued
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a. Office: A fire extinguisher was not mounted b. Loading Dock: A fire extinguisher was not mounted. c. Basement: A fire extinguisher was not mounted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Sep 11, 2012
- Abate by
- Dec 15, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Establishment: A written hazard communication program was not developed for chemicals in the work place including propane and battery acid. A written program shoud include the description of how the criteria for 1. Labeling and other forms of warning 2. Material Safety Data Sheets 3, Employee information and training, will be met
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423120)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334686003.