HIALEAH, FL ·
OSHA Inspection: CINDERELLA HOLDINGS II, LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of CINDERELLA HOLDINGS II, LLC in 1054 W 23 ST., HIALEAH, FL 33012 (NAICS 238140). OSHA activity number 334693785.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CINDERELLA HOLDINGS II, LLC
- Site address
- 1054 W 23 ST.
- City
- HIALEAH
- State
- FL
- ZIP
- 33012
- Mailing
- 2335 WEST 12TH AVENUE, HIALEAH, FL 33010
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.95 A
- Issued
- Oct 1, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: On or about June 14, 2012, employees were observed working without hard hats.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1926.451 B01
- Issued
- Oct 1, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about June14, 2012, an employee was observed applying stucco from a scaffold that was not fully planked at approximately 25 feet above the ground.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 E01
- Issued
- Oct 1, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: On or about June 14, 2012 employees were observed accessing the scaffold using the cross braces.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 G04 I
- Issued
- Oct 1, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. On or about June 14,2012, an employee was observed applying stucco from a scaffold without guardrails at approximately 25 feet above the ground.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 H02 II
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about June 14, 2012, employees were observed working from multiple levels of a scaffold that was missing toe boards.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1926.452 C02
- Issued
- Oct 1, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about June 14, 2012, employees were observed working from a scaffold that was missing cross braces.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 C02
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about June 14, 2012, employees were observed working from a scaffold where the poles were supported by varying objects including but not limited to pieces of scrap wood.
Recent events (2)