OSHA Inspection: DEPENDABLE STAMPING CO. INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEPENDABLE STAMPING CO. INC. in 1160 E. 222ND ST., EUCLID, OH 44117 (NAICS 332116). OSHA activity number 334696580.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dependable Stamping CO. INC. — free Get an email when a new federal OSHA severe-injury report for Dependable Stamping CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
1160 E. 222ND ST.
City
EUCLID
State
OH
ZIP
44117
Mailing
1160 E. 222ND ST., EUCLID, OH 44117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
25
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 29, 2012
Abate by
Jan 3, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    On 6/29/2012, the roof above the shipping office/lunch room is used as a storage platform for material such as, but not limited to shrink wrap. The platform was 12 feet above the dock side and 8 feet above the work floor side. The standard guard railing system did not have midrails.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 29, 2012
Abate by
Dec 19, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On 6/29/2012, the following machines were not properly guarded:    a. The Amada horizontal bandsaw had 2.5 inches of the unused portion of the saw blade that was not guarded.  b. There were two Clausing drill presses that did not have rotating chuck and tooling guarding.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.212 A03 II

Deleted Serious Gravity 5 3 instances 2 exposed
Issued
Nov 29, 2012
Abate by
Dec 19, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On 6/29/2012, the following press brakes had presence sensing devices (light curtains) at the front with openings at the sides of the press brakes that were not guarded:    a. Cincinnati, 175 ton press brake, number 302.  b. Cincinnati 90 ton press brake, number 306.  c. Cincinnati 60 ton press brake, number 309.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.212 B

Serious Gravity 5 7 instances 10 exposed
Issued
Nov 29, 2012
Abate by
Dec 19, 2012
Penalty
Initial $3,500 · Current $1,550 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On 6/29/2012, the following machines were not properly anchored and secured to the workfloor:    a. Cincinnati, 60 ton hydraulic press brake, number 309.  b. Bliss, 60 ton pneumatic/mechanical powered presses, number 061 and number 062.  c. Bliss, 75 ton pneumatic/mechanical powered press, number 320.  d. Bliss, 100 ton pneumatic/mechanical powered press, number 321.  e. Clausing, two vertical drill presses.
Recent events (2)
  • — I (S) $1550
  • — Z (S) $3500

1910.215 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 29, 2012
Abate by
Dec 9, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    On 6/29/2012, the Hammond abrasive wheel pedestal grinder had a work rest with an opening of 5/16 of an inch.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 29, 2012
Abate by
Dec 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On 6/29/2012, the Hammond abrasive wheel pedestal grinder had a periphery guard opening of 3/4 of an inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I A

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 29, 2012
Abate by
Dec 19, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):    On 6/29/2012, the number 054 Warco pneumatic/mechanical powered press had a presence sensing device (light curtain) for guarding with an opening at the side and over the top.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.242 B

Serious Gravity 5 2 instances 10 exposed
Issued
Nov 29, 2012
Abate by
Dec 19, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On 6/15/2012 and 6/29/2012, the employer was using compressed air at 65 psi for cleaning parts and machinery.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 29, 2012
Abate by
Dec 9, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On 6/29/2012, the employer had an electrical duplex receptacle with an open ground. The receptacle was mounted at the side of the number 321 Bliss 100 ton pneumatic/mechanical powered press.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

View Dependable Stamping CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334696580.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.