HALIFAX, PA —
OSHA Inspection: HEARTH & HOME TECHNOLOGIES, INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HEARTH & HOME TECHNOLOGIES, INCORPORATED in 352 MOUNTAIN HOUSE ROAD, HALIFAX, PA 17032 (NAICS 333414). OSHA activity number 334703394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEARTH & HOME TECHNOLOGIES, INCORPORATED
- Site address
- 352 MOUNTAIN HOUSE ROAD
- City
- HALIFAX
- State
- PA
- ZIP
- 17032
- Mailing
- 352 MOUNTAIN HOUSE ROAD, HALIFAX, PA 17032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333414
- Employees
- 169
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 14, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) CH-Line, Bending - Operators of the Trumpf TrumaBend V85 press brake, machine number 085, did set up activities, for example, die-setting on the press brake, which exposed the operator to caught-in or struck-by hazards, etc., and the operators did not utilize lockout/tagout when doing the set up activities, on or about June 13, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and shall state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.212 A03 II
- Issued
- Aug 14, 2012
- Abate by
- Apr 30, 2013
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: (a) CH-Line, Bending - Employees used a foot pedal to operate the Trumpf TrumaBend V85 press brake, machine number 085. Employees bent some work pieces which required the employees to get their hands to within 4 inches of the point of operation, and the press operator did not utilize any point of operation guarding for this work, on or about June 13, 2012. (b) CH-Line, Bending - Employees bent some large pieces on the Trumpf TrumaBend V85 press brake, machine number 085, that required the press operator and a helper to hold. The press had one foot pedal, which the press operator used to cycle the press, but the helper had no foot pedal and no other protection from the point of operation for this work, on or about June 13, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and shall state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.253 B04 I
- Issued
- Aug 14, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment: (a) Outdoors Compressed Gas Cylinder Storage Area - The employer had cylinders of oxygen stored next to cylinders of acetylene and methane, on or about June 13, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and shall state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
More inspections in this industry (NAICS 333414)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334703394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.