SAINT LOUIS, MO ·
OSHA Inspection: SCHAEFER AUTOBODY CENTER
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SCHAEFER AUTOBODY CENTER in 9902 WATSON RD., SAINT LOUIS, MO 63126 (NAICS 811121). OSHA activity number 334705399.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHAEFER AUTOBODY CENTER
- Site address
- 9902 WATSON RD.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63126
- Mailing
- 9902 WATSON RD., SAINT LOUIS, MO 63126
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 22
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.334 A03 II
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles: a. Two extension cords, used together with a "power strip" to power a 110 V fan, were missing ground pins. Abatement documentation is required for this violation.
Recent events (1)
- · Z (S) $1020
1910.303 B02
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. A relocatable power tap (power strip) was plugged into an extension cord in violation of its listing. b. A relocatable power tap was used in an industrial setting to power industrial equipment. Abatement documentation is required for this violation.
Recent events (1)
- · Z (S) $0
1910.134 F01
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. An employee, assigned to wear a half mask, cartridge respirator was not fit tested. Abatement documentation is required for this violation.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334705399.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.