OSHA Inspection: PERONE'S AUTO SERVICE & SALVAGE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PERONE'S AUTO SERVICE & SALVAGE, INC. in 371 ROUTE 22 EAST, GREEN BROOK, NJ 08812 (NAICS 423140). OSHA activity number 334706397.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Perone'S Auto Service & Salvage, INC. — free Get an email when a new federal OSHA severe-injury report for Perone'S Auto Service & Salvage, INC. is published. One employer, no account, unsubscribe in one click.
Site address
371 ROUTE 22 EAST
City
GREEN BROOK
State
NJ
ZIP
08812
Mailing
371 ROUTE 22 EAST, GREEN BROOK, NJ 08812
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423140
Employees
6
Ownership type
A

2 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 25, 2012
Penalty
Initial $2,000 · Current $2,000

Hazardous substances X100

29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gas cylinders shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in 1910.6:    a/ Perone's Auto Service & Salvage, Inc., Green Brook, NJ site: The employer failed to develop a safe procedure for the disposal of Compressed Gas Tanks.    Reference:    Compressed Gas Association Pamphlet P-1-1965  Sections 3.1.14 through 3.1.15 and 3.1.21 "Safe Handling Rules for Cylinders of Compressed Gases"      Condition observed on or about June 15, 2012.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.253(b)(4)(iii):  Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.    a/  Perone's Auto Service & Salvage Inc. - Green Brook, NJ Site - Gas Storage Area:  Acetylene (mixed sizes) and Oxygen (mixed sizes) fuel/gas cylinders were not seperated by a minimum 20 feet or an approved barrier, when not connected for use.    Observed on or about June 15/2012.