FALL RIVER, MA —
OSHA Inspection: PARAMOUNT TOOL, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PARAMOUNT TOOL, LLC in 473 PLEASANT STREET, FALL RIVER, MA 02721 (NAICS 332999). OSHA activity number 334718186.
Where did this inspection happen?
- Establishment
- PARAMOUNT TOOL, LLC
- Site address
- 473 PLEASANT STREET
- City
- FALL RIVER
- State
- MA
- ZIP
- 02721
- Mailing
- 473 PLEASANT STREET, FALL RIVER, MA 02721
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 30
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Machine-specific energy control procedures were not developed, documented or utilized for employees setting up or performing maintenance on equipment such as hydraulic presses, and mechanical power presses.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $893.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Facility: Employees operating forklifts were not re-evaluated on their performance at least every three years.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by moving parts: 1) 1st Floor: The lead screw for the Clausing Colchester 15" lathe was not guarded. 2) 2nd Floor: The 2-hand control buttons for the Denison Multipress #13 were not protected from accidental activation. 3) TTC: The rollers on the feed side of the Waterbury Farrel progressive feed were not guarded.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: 455 Pleasant Street - TTC: The outer safety guards for the Central Machinery Bench Grinder had been removed.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $893.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: 455 Pleasant Street - TTC: The work rest on the left side of the Central Machinery Bench Grinder was positioned 1 3/4-inch from the periphery of the abrasive wheel.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: 455 Pleasant Street - TTC: The tongue guard on the left side of the Central Machinery Bench Grinder was positioned 1 3/4-inches from the periphery of the abrasive wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C01 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): 455 Pleasant Street building - TTC: The following part revolution mechanical power presses operating in continuous mode were not equipped with a point of operation guard or device: 1. Rousselle Punch Press No. 4 (#222) 2. V&O press (orange - no number) 3. V&O press (#9) 4. Perkins press (#66).
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1190.00 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): 455 Pleasant Street building - TTC: The Rousselle Punch Press No. 4 (#222) was not equipped with a guard for the inside portion of the flywheel.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: 455 Pleasant Street - Loading dock: Two oxygen cylinders were stored next to an acetylene cylinder in the cylinder storage area.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $893.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: 455 Pleasant Street - TTC - A temporary makeshift electrical controller located behind the Rousselle Punch Press No. 4 (#222) powering the autofeed was used in place of fixed wiring.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.217 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: 455 Pleasant Street building - TTC: The mechanical power presses in this location were not inspected on a regular and periodic basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334718186.