OSHA Inspection: PARAMOUNT TOOL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PARAMOUNT TOOL, LLC in 473 PLEASANT STREET, FALL RIVER, MA 02721 (NAICS 332999). OSHA activity number 334718186.

Watch Paramount Tool, LLC — free Get an email when a new federal OSHA severe-injury report for Paramount Tool, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PARAMOUNT TOOL, LLC
Site address
473 PLEASANT STREET
City
FALL RIVER
State
MA
ZIP
02721
Mailing
473 PLEASANT STREET, FALL RIVER, MA 02721
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
30
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1488.00 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Machine-specific energy control procedures were not developed, documented or utilized for employees setting up or performing maintenance on equipment such as hydraulic presses, and mechanical power presses.
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

1910.178 L04 III

Serious Gravity 1 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    Facility:  Employees operating forklifts were not re-evaluated on their performance at least every three years.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1488.00 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by moving parts:    1)  1st Floor:  The lead screw for the Clausing Colchester 15" lathe was not guarded.    2)  2nd Floor:  The 2-hand control buttons for the Denison Multipress #13 were not protected from accidental activation.    3)  TTC:  The rollers on the feed side of the Waterbury Farrel progressive feed were not guarded.
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

1910.215 A02

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1488.00 Reduced
29 CFR 1910.215(a)(2):     Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    455 Pleasant Street - TTC:  The outer safety guards for the Central Machinery Bench Grinder had been removed.
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    455 Pleasant Street - TTC:  The work rest on the left side of the Central Machinery Bench Grinder was positioned 1 3/4-inch from the periphery of the abrasive wheel.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    455 Pleasant Street - TTC:  The tongue guard on the left side of the Central Machinery Bench Grinder was positioned 1 3/4-inches from the periphery of the abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 5 4 instances 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1488.00 Reduced
29 CFR 1910.217(c)(1)(i):     The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):    455 Pleasant Street building - TTC:  The following part revolution mechanical power presses operating in continuous mode were not equipped with a point of operation guard or device:    1.  Rousselle Punch Press No. 4 (#222)  2.  V&O press (orange - no number)  3.  V&O press (#9)  4.  Perkins press (#66).
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

1910.219 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.219(b)(1):     Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv):    455 Pleasant Street building - TTC:  The Rousselle Punch Press No. 4 (#222) was not equipped with a guard for the inside portion of the flywheel.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1488.00 Reduced
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    455 Pleasant Street - Loading dock:  Two oxygen cylinders were stored next to an acetylene cylinder in the cylinder storage area.
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    455 Pleasant Street - TTC - A temporary makeshift electrical controller located behind the Rousselle Punch Press No. 4 (#222) powering the autofeed was used in place of fixed wiring.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

1910.217 E01 I

Other-than-serious 5 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(e)(1)(i):     A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:    455 Pleasant Street building - TTC:  The mechanical power presses in this location were not inspected on a regular and periodic basis.