OSHA Inspection: U.S. DEPARTMENT OF NAVY - NCTMS, CRITICAL INFRASTRUCTURE SUPPORT (CIS)
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. DEPARTMENT OF NAVY - NCTMS, CRITICAL INFRASTRUCTURE SUPPORT (CIS) in CRITICAL INFRASTRUCTURE SUPPORT (CIS), ANTENNAE ENGINEERING VARIOUS, ANDERSON AIR FORCE BASE, DEDEDO, GU 96929 (NAICS 928110). OSHA activity number 334729399.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- CRITICAL INFRASTRUCTURE SUPPORT (CIS), ANTENNAE ENGINEERING VARIOUS, ANDERSON AIR FORCE BASE
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- PSC 455, BOX 195 FPO AP, DEDEDO, GU 96912
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 100
- Ownership type
- Federal government (D)
Citations
9 citations on file for this inspection.
1910.36 D01
- Issued
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: On or about 6/18/12, and at times prior thereto, exit doors were locked in the following locations: a. HVAC Dept, Bldg. 337: The exit door was locked with a latch. b. Power Production, Bldg. 337 c. High Voltage, Bldg. 336, near men's room
Recent events (1)
- · Z (S) $0
1910.107 E02
- Issued
- Nov 14, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(2): Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner. Antennae Dept., Spray Room: On or about 6/18/12, and at times prior thereto, a 5-gallon can of lacquer thinner (Sunnyside, Flash Point 0 degrees F) was stored in the spray room and exceeded the amount required for the day.
Recent events (1)
- · Z (S) $0
1910.107 E04
- Issued
- Nov 14, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(4): Adequate precautions were not taken to protect against liquid spillage and sources of ignition when transferring flammable or combustible liquids: Antennae Dept., Spray Room: On or about 6/18/12, and at times prior thereto, a 5-gallon can of Sunnyside lacquer thinner (Class 1B flammable) was poured directly into the spray gun container. Both the size and the weight of the can increased the chance of spillage.
Recent events (1)
- · Z (S) $0
1910.107 E09
- Issued
- Nov 14, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(9): Grounding. Whenever flammable or combustible liquids are transferred from one container to another, both containers shall be effectively bonded and grounded to prevent discharge sparks of static electricity. Antennae Dept., Spray Room: On or about 6/18/12, and at times prior thereto, it was noted that flammable lacquer thinner (Sunnyside, Flash Point 0 degrees F) was not bonded to the spray gun when being dispensed.
Recent events (1)
- · Z (S) $0
1910.107 G02
- Issued
- Nov 14, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: Antennae Dept., Spray Room: on or about 6/18/12, and at times prior thereto, combustible PSX Engineering Siloxane 700 overspray residue had excessively accumulated on the exterior spray room exit door.
Recent events (1)
- · Z (S) $0
1910.107 G03
- Issued
- Nov 14, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(3): Residue disposal. Residue scrapings and debris contaminated with residue shall be immediately removed from the premises and properly disposed of. Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily or at the end of each shift. Antennae Dept., Spray Room: Onor about 6/18/12, and at times prior thereto, rags and other combustible materials soaked wiith flammable Sunnyside Laquer Thinner (Class 1B, Flash Point 0 degrees F) and spray paint residue (PSX 700 Engineered Siloxane Coating) were discarded into an open, plastic trash can instead of an approved metal receptacle with a lid.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Nov 14, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: UPS, Bldg. 114: On or about 6/18/12, and at times prior thereto, a Dayton bench grinder, MD.# 2Z341L, had a measured 1/2 inch gap between the tongue guard and the grinding wheel.
Recent events (1)
- · Z (S) $0
1910.253 B02 IV
- Issued
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: HVAC, Bldg. 336, Storage Room: On or about 6/18/12, and at times prior thereto, two oxygen cylinders not in use did not have have valve caps in place.
Recent events (1)
- · Z (S) $0
1910.253 B04 III
- Issued
- Nov 14, 2012
- Abate by
- Nov 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a. HVAC, Bldg. 336, outdoor cylinder storage cage: On or about 6/18/12, and at times prior thereto, numerous oxygen and acetylene cylinders not is use were stored together. b. HVAC, Bldg. 336, Storage Room: On or about 6/18/12, and at times prior thereto, two cylinders of oxygen and one cylinder of acetylene were stored together when not in use.