PHILADELPHIA, PA —
OSHA Inspection: GARFIELD REFINING COMPANY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GARFIELD REFINING COMPANY in 810 EAST CAYUGA STREET, PHILADELPHIA, PA 19124 (NAICS 331419). OSHA activity number 334732195.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARFIELD REFINING COMPANY
- Site address
- 810 EAST CAYUGA STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19124
- Mailing
- 810 EAST CAYUGA STREET, PHILADELPHIA, PA 19124
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331419
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.95 C01
- Issued
- Aug 10, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95 (c)(1) The employer did not administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent. For purposes of the hearing conservation program, employee noise exposures shall be computed in accordance with appendix A and Table G-16a, and without regard to any attenuation provided by the use of personal protective equipment: a. An employee who operated the one small gas-fired tilt furnace and six small gas-fired furnaces in the Furnace Area was exposed to continuous noise at 71.8 % which exceeds the action level of 50% (an 8-hour time weighted average [TWA] sound level of 85 dBA) for instituting a hearing conservation program. The 8-hour TWA sound level was approximately 87.4 during the 250 minute sampling period on July 15, 2012. Exposure calculations included a zero increment for the 230 minutes not sampled. The employer did not establish an effective hearing conservation program.
Recent events (1)
- — Z (O) $0
1910.95 D01
- Issued
- Aug 10, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95 (d)(1): When information indicates that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a. An employee who operated the one small gas-fired tilt furnace and six small gas-fired furnaces in the Furnace Area was exposed to continuous industrial noise above the OSHA Action Level of 50% (an 8-hour time weighted average TWA sound level of 85 dBA) on June 15, 2012. The employer did not conduct representative noise exposure monitoring. For exposure information view Citation Number 01, Item Number 001.
Recent events (1)
- — Z (O) $0
1910.95 G01
- Issued
- Aug 10, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95 (g)(1): The employer did not establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a. An employee who operated the one small gas-fired tilt furnace and six small gas-fired furnaces in the Furnace Area was exposed to continuous industrial noise above the OSHA Action Level of 50% (an 8-hour time weighted average TWA sound level of 85 dBA) on June 15, 2012. The employer did not establish an audiometric testing program. For exposure information view Citation Number 01, Item Number 001.
Recent events (1)
- — Z (O) $0
1910.95 K01
- Issued
- Aug 10, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95 (k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time weighted average of 85 decibels in accordance with the requirements of this section. The employer shall institute a training program and ensure employee participation in the program: a. An employee who operated the one small gas-fired tilt furnace and six small gas-fired furnaces in the Furnace Area was exposed to continuous industrial noise above the OSHA Action Level of 50% (an 8-hour time weighted average TWA sound level of 85 dBA) on June 15, 2012. The employer did not establish an audiometric training program. For exposure information review Citation Number 01, Item Number 001.
Recent events (1)
- — Z (O) $0
1910.134 E01
- Issued
- Aug 10, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $0 · Current $0
2240
General-duty citation text
29 CFR 1910.134(e)(1): General. The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator: a. Furnace Area The employer did not ensure that employees were medically evaluated prior to fit testing and initial use of their respirators. These employees wore 3M 5203 half-mask air purifying respirators (dual cartridge organic vapor and 3M 5N11, N95 pancake filters). Observed On or About June 14, 2012
Recent events (1)
- — Z (O) $0
1910.134 F02
- Issued
- Aug 10, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $0 · Current $0
2240
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a. Furnace Area The employer did not ensure that employees were fit tested prior to initial use of their respirators. These employees wore 3M 5203 half-mask air purifying respirators (dual cartridge organic vapor and 3M 5N11, N95 pancake filters). Observed On or About June 14, 2012
Recent events (1)
- — Z (O) $0
1910.147 C06 I
- Issued
- Aug 10, 2012
- Abate by
- Aug 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147 (c)(6)(i) The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a. Facility The employer did not conduct the certification of annual periodic inspections in order to verify and to ensure that the energy control procedures are being properly utilized. The periodic inspection is intended to assure that the energy control procedures continue to be implemented properly, and that the employees involved are familiar with their responsibilities under those procedures. Observed On or About June 14, 2012
Recent events (1)
- — Z (O) $0
More inspections at Garfield Refining Company
View Garfield Refining Company's full OSHA safety record →
More inspections in this industry (NAICS 331419)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334732195.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.