OSHA Inspection: CAPITAL ONE CONSTRUCTION, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITAL ONE CONSTRUCTION, INC in 3589 THIRD AVE, BRONX, NY 10456 (NAICS 236210). OSHA activity number 334740602.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital ONE Construction, INC — free Get an email when a new federal OSHA severe-injury report for Capital ONE Construction, INC is published. One employer, no account, unsubscribe in one click.
Site address
3589 THIRD AVE
City
BRONX
State
NY
ZIP
10456
Mailing
242 JOHNSON AVE, BROOKLYN, NY 11206
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 5 instances 5 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury    On or about 6/19/2012, Job Site    a) The employees were not provided safety and health training as required by the standard.
Recent events (1)
  • — Z (S) $1320

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:    On or about 6/19/2012, Job Site    a) The employees used electrical tools with the tempporary power and they were not protected by using a ground fault circuit interrupter.
Recent events (1)
  • — Z (S) $1320

1926.404 F06

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous:    On or about 6/19/2012, Job Site    a) The outlet box had an open ground and the extension cord had the ground pin broken off.
Recent events (1)
  • — Z (S) $1320

1926.405 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.405(b)(2): Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear:    On or about 6/19/2012, 1st Floor    a) The main electrical panel box and an outlet box was not covered.
Recent events (1)
  • — Z (S) $1320

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used:    On or about 6/19/2012    a) The extension cord used to energize the grinder was damaged.
Recent events (1)
  • — Z (S) $1320

1926.701 B

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 3, 2012
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement:    On or about 6/19/2012, 2nd Floor    a) The rebars were not capped.
Recent events (1)
  • — Z (S) $1320

View Capital ONE Construction, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334740602.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.