BRONX, NY ·
OSHA Inspection: GS IRON WORKS, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of GS IRON WORKS, INC in 3589 THIRD AVE, BRONX, NY 10456 (NAICS 238120). OSHA activity number 334742194.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GS IRON WORKS, INC
- Site address
- 3589 THIRD AVE
- City
- BRONX
- State
- NY
- ZIP
- 10456
- Mailing
- 238 JOHNSON AVE, BROOKLYN, NY 11206
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Aug 3, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: On or about 6/19/2012, Job Site a) The employees were not provided safety and health training as required by the standard.
Recent events (1)
- · Z (S) $1020
1926.404 B01 I
- Issued
- Aug 3, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: On or about 6/19/2012, 2nd Floor a) The employee was using electrical tools. He was not using a ground fault circuit interrupter.
Recent events (1)
- · Z (S) $1200
1926.405 B01
- Issued
- Aug 3, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed: On or about 6/19/2012, 2nd Floor a) The employee used the outlet box to energize his tool. The punch outs were missing.
Recent events (1)
- · Z (S) $1200
1926.451 B01
- Issued
- Aug 3, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: On or about 6/19/2012, South Side of the Building a) The employee worked from one aluminum plank on the scaffold. The scaffold was not fully planked.
Recent events (1)
- · Z (S) $2400
1926.451 E01
- Issued
- Aug 3, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access: On or about 6/19/2012, South Side a) The employee climbed on the scaffold frame to gain access to the scaffold platform.
Recent events (1)
- · Z (S) $1200
1926.451 G01
- Issued
- Aug 3, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part: On or about 6/19/2012, South Side a) The employee worked from the tubular welded frame scaffold approximately 18' high and was not protected by a guardrail system.
Recent events (1)
- · Z (S) $2800
1926.701 B
- Issued
- Aug 3, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement: On or about 6/19/2012, 2nd Floor a) There were rebars that were not capped, exposing the employee to an impalement hazard.
Recent events (1)
- · Z (S) $1200
1926.403 G
- Issued
- Aug 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(g): Marking. Electrical equipment shall not be used unless the manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product may be identified is placed on the equipment and unless other markings are provided giving voltage, current, wattage, or other ratings as necessary. The marking shall be of sufficient durability to withstand the environment involved: On or about 6/19/2012, 2nd Floor a) The wrench used to secure the bolts was not labeled.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 238120)