AMHERST, NY ·
OSHA Inspection: SYNERGY TOOLING SYSTEMS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SYNERGY TOOLING SYSTEMS in 287 COMMERCE DRIVE, AMHERST, NY 14228 (NAICS 333514). OSHA activity number 334760188.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SYNERGY TOOLING SYSTEMS
- Site address
- 287 COMMERCE DRIVE
- City
- AMHERST
- State
- NY
- ZIP
- 14228
- Mailing
- 287 COMMERCE DRIVE, AMHERST, NY 14228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- Employees
- 30
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 06/20/12, in the production areas, a Lockout/Tagout procedure was not utilized when cleaning ACS 100 Elcede CIM_Line machine. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (S) $1785
1910.147 C06 I
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) On or about 06/20/12, in the establishment, Employer did not perform periodic inspections of their specific lockout/tagout procedures for machines such as, but not limited to: ACS 100 Elcede CIM_LINE, Easy Bender Turbo SDS Model EBT-200 Serial 0673, Elcede Countermate Pro/Steel Counterplate Cutter, Elcede Lasermate 3000. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.147 C06 II
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) On or about 06/20/12, in the establishment, Employer did not have certifications showing that their specific lockout/tagout procedures for machines such as, but not limited to: ACS 100 Elcede CIM_LINE, Easy Bender Turbo SDS Model EBT-200 Serial 0673, Elcede Countermate Pro/Steel Counterplate Cutter, Elcede Lasermate 3000, had been inspected by an authorized employee at least annually. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 B
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about 06/20/12, in the Tooling Department, a Shop Fox Drill Press was not anchored to floor. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $892.5
- · Z (S) $1785
1910.215 A04
- Issued
- Jul 9, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about 06/20/12, in the die shop area, a Baldor CAT No 712E Bench Grinder's workrest was adjusted to 5/16 inch. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $892.5
- · Z (S) $1785
1910.215 B09
- Issued
- Jul 9, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 06/20/12, in the die-shop area, a Baldor CAT No 712E Bench Grinder's tongue guard was adjusted to 7/8 inch. b) On or about 06/20/12, in the die-shop area, a Dayton Bench Grinder's tongue guard was adjusted to 5/16 inch. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Synergy Tooling Systems
View Synergy Tooling Systems's full OSHA safety record →
More inspections in this industry (NAICS 333514)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334760188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.