COLORADO SPRINGS, CO ·
OSHA Inspection: FIXINS HOME SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FIXINS HOME SERVICES in 928 N. WEBER, COLORADO SPRINGS, CO 80907 (NAICS 238160). OSHA activity number 334770591.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIXINS HOME SERVICES
- Site address
- 928 N. WEBER
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80907
- Mailing
- 3125 N. WEBER, COLORADO SPRINGS, CO 80907
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about June 14, 2012, employer did not ensure that employees were protected from falls in excess of 20 feet while working from scaffolds where the scaffolds were not fully planked.
Recent events (1)
- · Z (S) $2800
1926.454 A
- Issued
- Sep 18, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about June 14, 2012, employer did train employees to work from scaffolds, recognize the hazards associated with the scaffold, and minimize the hazards .
Recent events (1)
- · Z (S) $0
1926.451 C01 II
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide: a) On or about June 14, 2012, employer did not ensure that employees were protected from scaffold collapse while working off of scaffolds in excess of 20 feet where the scaffolds were not tie off the building.
Recent events (1)
- · Z (S) $2800
1926.451 C02
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about June 14, 2012, employer did not ensure that employees were protected from scaffold collapse while working off of scaffolds in excess of 20 feet where the scaffold did not have mudsills under the base plates.
Recent events (1)
- · Z (S) $0
1926.451 E01
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): Crossbraces were used as a means of access: a) On or about June 14, 2012, employer did not ensure that employees were protected from falls in excess of 20 feet where the employees were accessing the top platform of the scaffold using the crossbraces.
Recent events (1)
- · Z (S) $0
1926.451 G04 I
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a) On or about June 14, 2012, employer did not ensure that employees were protected from falls in excess of 20 feet while working off of scaffolds where the scaffolds did not have guardrails.
Recent events (1)
- · Z (S) $0
More inspections at Fixins Home Services
View Fixins Home Services's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334770591.