Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: CARUSO ELECTRIC INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CARUSO ELECTRIC INC. in 1180 JEFFERSON ROAD, ROCHESTER, NY 14623 (NAICS 238210). OSHA activity number 334785425.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Caruso Electric INC. — free Get an email when a new federal OSHA severe-injury report for Caruso Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
1180 JEFFERSON ROAD
City
ROCHESTER
State
NY
ZIP
14623
Mailing
608 TRABOLD ROAD, ROCHESTER, NY 14624
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.28 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Oct 17, 2012
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.28(a):     Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions:    a) On or about 6/19/12 in the Boiler Room at Sutherland Global Services Rochester, New York;  employee removed the front protective covers on Section 1 of the ( 480Y/277V, 3 phase 4 wire 1600 amp ) Challenger "Power Master" switchboard exposing energized electrical parts and was required to wear a faceshield, flame resistant clothing, hearing protection and voltage rated protective gloves prior to placing a 30 amp circuit breaker far enough into the #3 slot on the energized switchboard causing an arc flash/ arc blast.      Abatement Documentation
Recent events (3)
  • — J (S) $1000
  • — C (S) $2800
  • — Z (S) $2800

1926.95 A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 17, 2012
Abate by
Oct 17, 2012
Penalty
Initial $2,160 · Current $0 Reduced
29 CFR 1926.95(a):     Personal protective equipment, including personal protective equipment for extremities ( hands and arms ) was not maintained in reliable condition when it was necessary by reason of hazards of the environment, encountered in a manner capable of causing injury or impairment in the function of any part of the body through physical contact.    a) On or about 6/19/12 at Sutherland Global Services Rochester, New York; voltage rated gloves ( White Rubber Corp - Size 10, Class 0 ) were last tested approximately five years ago.      No Abatement Documentation
Recent events (3)
  • — J (S) $0
  • — C (S) $2160
  • — Z (S) $2160

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Oct 17, 2012
Penalty
Initial $2,800 · Current $500 Reduced
29 CFR 1926.416(a)(1):     Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a) On or about 6/19/12 in the Boiler Room at Sutherland Global Services Rochester, New York; employee removed the front covers for circuit breakers #2 & #4 on Section 1 of the ( 480Y/277V, 3 phase 4 wire 1600 amp ) Challenger "Power Master" switchboard exposing energized electrical parts without providing any type of protective cover or guarding against contact with these parts.      Abatement Documentation
Recent events (3)
  • — J (S) $500
  • — C (S) $2800
  • — Z (S) $2800

1926.416 A03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Oct 30, 2012
Penalty
Initial $2,800 · Current $500 Reduced
29 CFR 1926.416(a)(3):     Employer did not advise employees of the the hazards involved and the protective measures to be taken:    a) On or about 6/19/12 in the Boiler Room at Sutherland Global Services Rochester, New York; employee (1) removed the three front covers on Section 1 of the ( 480Y/277V, 3 phase 4 wire 1600 amp ) Challenger "Power Master" switchboard and began to install a 30 amp circuit breaker into the #3 slot of the energized switchboard when an arc flash/arc blast occurred.  Employee (2) was assisting employee (1) by holding a flashlight to illuminate the work area in proximity to the energized switchboard.  Employee (1) did not advise employee (2) about the arc flash/arc blast hazards of working on or near energized electrical equipment nor the protective equipment to be worn.      Abatement Documentation
Recent events (3)
  • — J (S) $500
  • — C (S) $2800
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334785425.