Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: A & X CARPENTERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & X CARPENTERS in 5253 WATSON RD, WASHINGTON, DC 20013 (NAICS 236115). OSHA activity number 334791399.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & X Carpenters for free Get an email when a new federal OSHA severe-injury report for A & X Carpenters is published. One employer, no account, unsubscribe in one click.
Establishment
A & X CARPENTERS
Site address
5253 WATSON RD
City
WASHINGTON
State
DC
ZIP
20013
Mailing
11017 MARCLIFF RD, ROCKVILLE, MD 20852
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
8
Ownership type
Private (A)

3 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Aug 21, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    Third floor, south wall area - Employees were using portable extension cords, to power electrical equipment, that had the ground pin missing.
Recent events (3)
  • · R (S) $0
  • · C (S) $1200
  • · Z (S) $1200

1926.501 B13

Deleted Serious Gravity 10 4 instances 3 exposed
Issued
Aug 21, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) South Corner of Roof - Employees were standing on the top plate installing trusses without a personal fall arrest system in place to prevent them falling 35 to ground level.    b) Third floor, South Wall - Employees were working near open wall openings that was not equipped with a top rail measured vertically at 42 inches.  Employees were exposed to a fall from elevation of approximately 35 ft. to the ground below.
Recent events (3)
  • · R (S) $0
  • · C (S) $2800
  • · Z (S) $2800

1926.1053 B01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 21, 2012
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) Third Floor, South wall - Employees were using a step ladder, to access the top plate area, that was flush to the landing platform.
Recent events (3)
  • · R (S) $0
  • · C (S) $2400
  • · Z (S) $2400

View A & X Carpenters's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334791399.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.