Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PERGAN MARSHALL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERGAN MARSHALL, LLC in 710 BUSSEY ROAD, MARSHALL, TX 75670 (NAICS 325199). OSHA activity number 334793395.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pergan Marshall, LLC — free Get an email when a new federal OSHA severe-injury report for Pergan Marshall, LLC is published. One employer, no account, unsubscribe in one click.
Site address
710 BUSSEY ROAD
City
MARSHALL
State
TX
ZIP
75670
Mailing
710 BUSSEY ROAD, MARSHALL, TX 75670
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
42
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 13, 2012
Abate by
Dec 26, 2012
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.22(a)(1):      All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:    This violation was discovered on July 27, 2012; in the maintenance parts warehouse where parts, pallets and equipment were cluttering up passageways.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.22 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 13, 2012
Abate by
Dec 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2):     Floor(s) of workroom(s) were not maintained in a so far as possible, a dry condition:    This violation was discovered on July 27, 2012; in the compressor room where water and oil on the floor resulted in a wet, slippery surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 E03 I

Serious Gravity 10 1 instance 42 exposed
Issued
Dec 13, 2012
Abate by
Apr 1, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.119(e)(3)(i):     The process hazard analysis did not address all hazards involved in the process:    This violation was discovered on, July 6, 2012; where all utility systems that could affect or cause a release of highly hazardous chemicals or interfere in the mitigation of the consequences of a release were not addressed in the process hazard analysis.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.119 J04 III

Serious Gravity 5 15 instances 42 exposed
Issued
Dec 13, 2012
Abate by
Apr 1, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.119(j)(4)(iii):     The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, or more frequently if determined to be necessary by prior operating experience:    This violation was discovered on August 16, 2012 as described below:     a.)  The Ultrasonic Thickness inspection for R-100 due on January 22, 2011 was not completed.  b.)  The External Visual inspection for R-100 due on November 28, 2008 was not completed.  c.)  The Ultrasonic Thickness inspection for R-200 due on October 04, 2011 was not completed.  d.)  The External Visual inspection for R-100 due on July 4, 2009 was not completed.  e.)  The Ultrasonic Thickness inspection for R-400A due on October 04, 2011 was not completed.  f.)   The External Visual inspection for R-400A due on October 04, 2011 was not completed.  g.)  The Internal inspection for R-400A due on August 16, 2012 was not completed.  h.)  The Ultrasonic Thickness inspection for R-400B due on October 04, 2011 was not completed.  i.)   The External Visual inspection for R-400B due on October 04, 2011 was not completed.  j.)   The Internal inspection for R-400B due on August 16, 2012 was not completed.  k.)  The Ultrasonic Thickness inspection for R-400C due on October 05, 2011 was not completed.  l.)   The External Visual inspection for R-400C due on October 05, 2011 was not completed.  m.) The annual internal inspection for T-900 was last completed on October 9, 2007.  n.)  The annual internal inspection for T-910 was last completed on October 9, 2007.  o.)  The annual internal inspection for T-920 was last completed on October 9, 2007.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C04 II

Other-than-serious 1 instance 3 exposed
Issued
Dec 13, 2012
Abate by
Dec 26, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):     The employer's energy control procedures did not include speciific steps or procedures to be followed for purging lines, tanks, or vessels:      This violation was discovered on July 6, 2012; where employees performing maintenance activities did not have equipment specific procedures developed and documented to be utilized for the control of hazardous energy.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

View Pergan Marshall, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334793395.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.