Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAFAEL GARCIA CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAFAEL GARCIA CONSTRUCTION in 5211 FOREST DR, NEW ALBANY, OH 43054 (NAICS 238130). OSHA activity number 334799210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rafael Garcia Construction — free Get an email when a new federal OSHA severe-injury report for Rafael Garcia Construction is published. One employer, no account, unsubscribe in one click.
Site address
5211 FOREST DR
City
NEW ALBANY
State
OH
ZIP
43054
Mailing
446 ROTHGATE DRIVE, GROVEPORT, OH 43040
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.502 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 29, 2012
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1926.502(b)(1):     Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.  Note: When employees are using stilts, the top edge height of the top rail, or equivalent member, shall be increased an amount equal to the height of the stilts.    a. On the west side of the 4th floor of the hotel, where employees were cutting holes the top guardrail around the mechanical shaft was installed at 35 inches, thereby exposing employees to an approximately 40 foot fall hazard.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1926.502 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(2):     Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high.    a. On the west side of the 4th floor of the hotel, there was no midrail around the mechanical shaft where employees were cutting holes, thereby exposing employees to an approximately 40 foot fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 B03

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3):     Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge.    a. On the 3rd floor of the building where employees were cleaning, the midrail on the elevator shaft was damaged, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334799210.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.