OSHA Inspection: TEDCO CONSTRUCTION CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEDCO CONSTRUCTION CORPORATION in 300 CAMPUS DRIVE, PARKERSBURG, WV 26104 (NAICS 236220). OSHA activity number 334799392.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tedco Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Tedco Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
300 CAMPUS DRIVE
City
PARKERSBURG
State
WV
ZIP
26104
Mailing
TEDCO PLACE, CARNEGIE, PA 15106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2012
Abate by
Sep 18, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(10):      Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet(15.25 m) or less in width, the use of a safety monitoring system alone:    (a) Child Development Center:  Employees were conducting roofing activities, applying roof sheathing, on a roof with a slope of 3:12 that was 11 feet 4 inches above ground level without the use of fall protection, warning line system, or safety monitor, as observed on June 20, 2012.    Abatement Certification Required for this Item
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2012
Abate by
Sep 18, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.1053(b)(1):     Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed:    (a)Child Development Center:  Employees used a 6 foot Werner fiberglass step ladder to gain access to a low slope roof that was placed on a scaffold platform.  The step ladder was in the closed position and leaned against the roof eave, and the ladder did not extend 3 feet above the upper landing surface being accessed, as observed on June 20, 2012.        Abatement Certification Required for this Item
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2012
Abate by
Sep 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4):     Ladder(s) were used for purposes other than the purpose for which they were designed:    (a)Child Development Center:  Employees were using a 6 foot Werner fiberglass step ladder that was closed and leaned against the eave of a low slope roof.   The ladder was used to access the roof and the base of the step ladder was not fully opened and spreaders were not in the opened locked position, as observed on June 20, 2012.     Abatement Note:  One feasible and acceptable abatement method to correct this hazard is to select a ladder, such as an extension ladder placed on ground level, which extends three feet beyond the landing being accessed, and with both side rails firmly supported equally.        Abatement Certification Required for this Item