PATERSON, NJ —
OSHA Inspection: KIRKER ENTERPRISES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KIRKER ENTERPRISES, INC. in ONE EAST 11TH STREET, PATERSON, NJ 07524 (NAICS 325620). OSHA activity number 334802584.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KIRKER ENTERPRISES, INC.
- Site address
- ONE EAST 11TH STREET
- City
- PATERSON
- State
- NJ
- ZIP
- 07524
- Mailing
- ONE EAST 11TH STREET, PATERSON, NJ 07524
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325620
- Employees
- 50
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.119 D03 II
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) Processing department: The employer did not document in the process safety information the ventilation system redesign complies with recognized and generally accepted good engineering practices thus exposing employees to a potential explosive atmosphere due to a lack of sufficient air flow, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $4950
- — Z (S) $4950
1910.119 E03 II
- Issued
- Dec 17, 2012
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,950 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(ii): The process hazard analysis did not address the identification of any previous incident which has a likely potential for catastrophic consequences in the workplace. a) Processing department: Process hazard analysis did not identify previous incidents and near misses such as incidents where the incorrect amount of flammables were added which led to tank overflow, exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $4950
- — Z (S) $4950
1910.119 E03 IV
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $2,970
General-duty citation text
29 CFR 1910.119(e)(3)(iv): The process hazard analysis shall address: consequences of failure of engineering and administrative controls; a) Processing department: The process hazard analysis did not address the ventilation system underperformance thus exposing employees to a potential explosive atmosphere due to a lack of sufficient air flow, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $0
- — Z (S) $0
1910.119 E03 VI
- Issued
- Dec 17, 2012
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(3)(vi): The process hazard analysis shall address: human factors; a) Processing department: Process hazard analysis did not address the consequences of human error on the covered process such as, but not limited to, an incident involving an employee inadvertently overfilled mixing tank, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 F01 I
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(i): The employer shall develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and shall address at least the following elements: steps for each operating phase. a) Processing department: Operating procedure of gel manufacturing/homogenization, document No: KIR-WI-MFG 008 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Operating procedure of thermo-oxidizer, document No: KIR- SOP-014 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Operating procedure of static grounding and bonding, document No: KIR- SOP-MFG-003 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Operating procedure of base transfer to product tank, document No: KIR-WI-MFG-015 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. e) Processing department: Operating procedure of mix tank solvent loading, document No: KIR-WI-MFG-016 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. f) Processing department: Operating procedure of transfer of suspension base, document No: KIR- WI-MFG-017 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. g) Processing department: Operating procedure of manufacture of suspension base, document No: KIR-WI-MFG-005 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. h) Processing department: Operating procedure of tank washer, document No: KIR- WI-MFG-020 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. i) Processing department: Operating procedure of procedure for corrective steps for overage, document No: KIR- SOP-MFG-008 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12. j) Processing department: Operating procedure of manufacturing nail polish shades, document No: KIR-SOP-MFG-002 does not contain steps for each operating phase, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $4950
- — Z (S) $4950
1910.119 F01 II A
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1)(ii)(A): The employer shall develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and shall address at least the following elements: Consequences of deviation; a) Processing department: Operating procedure of gel manufacturing/homogenization, document No: KIR-WI-MFG 008 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Operating procedure of thermo-oxidizer, document No: KIR- SOP-014 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Operating procedure of static grounding and bonding, document No: KIR- SOP-MFG-003 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Operating procedure of base transfer to product tank, document No: KIR-WI-MFG-015 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. e) Processing department: Operating procedure of mix tank solvent loading, document No: KIR-WI-MFG-016 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. f) Processing department: Operating procedure of transfer of suspension base, document No: KIR- WI-MFG-017 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. g) Processing department: Operating procedure of manufacture of suspension base, document No: KIR-WI-MFG-005 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. h) Processing department: Operating procedure of tank washer, document No: KIR- WI-MFG-020 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. i) Processing department: Operating procedure of procedure for corrective steps for overage, document No: KIR- SOP-MFG-008 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. j) Processing department: Operating procedure of manufacturing nail polish shades, document No: KIR-SOP-MFG-002 does not address consequences of deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 F01 II B
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1)(ii)(B): The employer did not develop and implement written operating procedures that provide clear instructions for steps required to correct or avoid deviation from the operating limits in the covered process. a) Processing department: Operating procedure of gel manufacturing/homogenization, document No: KIR-WI-MFG 008 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Operating procedure of thermo-oxidizer, document No: KIR- SOP-014 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Operating procedure of static grounding and bonding, document No: KIR- SOP-MFG-003 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Operating procedure of base transfer to product tank, document No: KIR-WI-MFG-015 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. e) Processing department: Operating procedure of mix tank solvent loading, document No: KIR-WI-MFG-016 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. f) Processing department: Operating procedure of transfer of suspension base, document No: KIR- WI-MFG-017 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. g) Processing department: Operating procedure of manufacture of suspension base, document No: KIR-WI-MFG-005 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. h) Processing department: Operating procedure of tank washer, document No: KIR- WI-MFG-020 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. i) Processing department: Operating procedure of procedure for corrective steps for overage, document No: KIR- SOP-MFG-008 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12. j) Processing department: Operating procedure of manufacturing nail polish shades, document No: KIR-SOP-MFG-002 does not contain steps to correct or avoid deviation, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 F02
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.119(f)(2): Operating procedures shall be readily accessible to employees who work in or maintain a process. a) Processing department: Operating procedures for the covered process were not accessible to batchmakers, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $4950
- — Z (S) $4950
1910.119 F03
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(3): The employer shall certify annually that operating procedures are current and accurate. a) Processing department: Operating procedure of gel manufacturing/homogenization, document No: KIR-WI-MFG 008 was last reviewed on 04/18/07, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Operating procedure of thermo-oxidizer, document No: KIR-SOP-MFG-014 was last reviewed on 07/25/06, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Operating procedure of static grounding and bonding, document No: KIR- SOP-MFG-003 was last reviewed on 04/30/08, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Operating procedure of base transfer to product tank, document No: KIR-WI-MFG-015 was last reviewed on 09/18/01, thus exposing employees to a potential fire hazard, on or about 06/22/12. e) Processing department: Operating procedure of mix tank solvent loading, document No: KIR-WI-MFG-016 was last reviewed on 09/18/01, thus exposing employees to a potential fire hazard, on or about 06/22/12. f) Processing department: Operating procedure of transfer of suspension base, document No: KIR-WI-MFG-017 was last reviewed on 09/18/01, thus exposing employees to a potential fire hazard, on or about 06/22/12. g) Processing department: Operating procedure of manufacture of suspension base, document No: KIR-WI-MFG-005 was last reviewed on 12/02/04, thus exposing employees to a potential fire hazard, on or about 06/22/12. h) Processing department: Operating procedure of solvent dispensing, document No: KIR- WI-MFG-018 was last reviewed on 04/30/08, thus exposing employees to a potential fire hazard, on or about 06/22/12. i) Processing department: Operating procedure of facility shut down and lockup, document No: KIR-SOP-FAC-001 was last reviewed on 07/08/05, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 J02
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment a) Processing department: The employer did not establish and implement written procedures for inspection, testing, evaluation, and repair of process equipment such as, but not limited to, ventilation, grounding and bonding cable, and pumps, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $4950
- — Z (S) $4950
1910.119 J04 II
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures shall follow recognized and generally accepted good engineering practices: a) Processing department: Inspection and testing of process piping systems and piping components was not performed per recognized and generally accepted good engineering practice, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Inspection and testing of transfer pumps was not performed per recognized and generally accepted good engineering practice, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Inspection and testing of grounding wire was not performed per recognized and generally accepted good engineering practice, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Inspection and testing of ventilation system was not performed per recognized and generally accepted good engineering practice, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 J04 IV
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer shall document each inspection and test that was performed on process equipment: a) Processing department: Inspection and testing of process piping systems and piping components was not properly documented, thus exposing employees to a potential fire hazard, on or about 06/22/12. b) Processing department: Inspection and testing of transfer pumps was not properly documented, thus exposing employees to a potential fire hazard, on or about 06/22/12. c) Processing department: Inspection and testing of grounding wire was not properly documented, thus exposing employees to a potential fire hazard, on or about 06/22/12. d) Processing department: Inspection and testing of ventilation system was not properly documented, thus exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 L01
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.119(l)(1): The employer shall establish and implement written procedures to manage changes (except for "replacements in kind") to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process. a) Thermo-Ionizer: In 2005, The thermo-ionizer was changed, local ventilations were eliminated, and ventilation ductworks were resized, but written procedures to manage these changes were not established, thus exposing employees to potential explosive atmosphere due to a lack of air flow, on or about 06/22/12.
Recent events (3)
- — F (S) $2970
- — C (S) $4950
- — Z (S) $4950
1910.119 M01
- Issued
- Dec 17, 2012
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,950 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(m)(1): The employer shall investigate each incident which resulted in, or could reasonably have resulted in a catastrophic release of highly hazardous chemical in the workplace. a) Processing department: Near misses of the covered process were not investigated and documented such as, but not limited to, an incident involving an employee inadvertently overfilled mixing tank exposing employees to a potential fire hazard, on or about 06/22/12.
Recent events (3)
- — F (S) $0
- — C (S) $4950
- — Z (S) $4950
1910.119 D03 I E
- Issued
- Dec 17, 2012
- Abate by
- May 10, 2013
- Penalty
- Initial $9,900 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(E): Process safety information pertaining to the equipment in the process did not include ventilation system design; a) Large color matching room, building#1: A number of local ventilations were eliminated from the original ventilation design, but were not included in the drawing, thus exposing employees to potential explosive atmosphere due to a lack of air flow, on or about 06/22/12. b) Adjustment area mixers, building#2: A number of local ventilations were added, but were not included in the drawing, on or about 06/22/12. KIRKER ENTERPRISES, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER (312858988), CITATION NUMBER 1 ITEM NUMBER 6 ISSUED ON 11/05/2009 WHICH BECAME A FINAL ORDER ON 12/01/2009.
Recent events (3)
- — F (S) $4200
- — C (R) $9900
- — Z (R) $9900
More inspections at Kirker Enterprises, INC.
View Kirker Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325620)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334802584.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.