Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & F FRAMING, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & F FRAMING, LLC. in 113 KINGSTON STREET, ROSEMARY BEACH, FL 32461 (NAICS 238130). OSHA activity number 334807542.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & F Framing, LLC. — free Get an email when a new federal OSHA severe-injury report for J & F Framing, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
J & F FRAMING, LLC.
Site address
113 KINGSTON STREET
City
ROSEMARY BEACH
State
FL
ZIP
32461
Mailing
809 INDIAN WOMAN ROAD, SANTA ROSA BEACH, FL 32459
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 17, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.     a. On or about June 13, 2012, on the 3rd level of the structure, an employee performing framing operations was not protected from the hazard of falling 23 feet to the surface by use of a guardrail system, safety net system, personal fall arrest system or any fall protection.     b. On or about June 13, 2012, on the 2nd level of the structure, an employee performing framing operations was not protected from a 11.8 feet fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any fall protection.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1052 C04

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2012
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members, shall be provided between the top rail of the stairrail system and the stairway steps.    a. On or about June 13, 2012, employees used a stairway system that did not have a midrail system, screens or mesh establised, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2012
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.     a. On or about June 13, 2012, employees used a 20 ft. Louisville extension ladder to access the 3rd level of the structure that did not extend 3 ft. above the floor landing, exposing themselves to a fall hazard.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1926.1053 B15

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(15): Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.    a. On or about June 13, 2012, a 20 ft. Louisville extension ladder used by employees was not inspected for defects in that the foot pads were not locked into place,exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334807542.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.