Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WARREN OIL COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WARREN OIL COMPANY, INC. in 915 E. JEFFERSON, WEST MEMPHIS, AR 72301 (NAICS 326160). OSHA activity number 334834181.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Warren OIL Company, INC. — free Get an email when a new federal OSHA severe-injury report for Warren OIL Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
915 E. JEFFERSON
City
WEST MEMPHIS
State
AR
ZIP
72301
Mailing
915 E. JEFFERSON, WEST MEMPHIS, AR 72301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
200
Ownership type
A

5 citations on file for this inspection.

1910.36 D01

Other-than-serious 1 instance 35 exposed
Issued
Nov 6, 2012
Abate by
Nov 19, 2012
Penalty
Initial $5,500 · Current $2,750 Reduced
29 CFR 1910.36(d)(1):     Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:      On or about June 25, 2012, October 23, 2012 and at times prior thereto employees were possibly not able to open the south exit door of Building 327 from the inside at all times without keys, tools, or special knowledge because the door-knob lock device could be accidently or intentionally engaged. This exposed employees to a possible fire of greater intensity increasing the possibility of more severe burns, an increased amount of smoke inhalation and impaired visibility due to delay or the inability to unlock the door.
Recent events (2)
  • — I (O) $2750
  • — Z (S) $5500

1910.37 B02

Other-than-serious 2 instances 35 exposed
Issued
Nov 6, 2012
Abate by
Nov 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):     Each exit was not clearly visible and marked by a sign reading "EXIT"    On or about June 25, 2012,October 23, 2012 and at times prior thereto the south and east openings into an exit of Building 327 were not marked by a sign reading "EXIT". This exposed employees to a possible delay in finding or inability to find an exit opening therefore increasing the possibility of more severe burns and increased smoke inhalation.     Location:   a) South exit door of bldg. 327  b) East exit door of Bldg. 327
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Nov 6, 2012
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Instance a) On or about June 25, 2012 in the blow mold department, employees operating the bottle leak detector machines were exposed to being struck by rotating parts because the front doors of the machine enclosure were missing.    Instance b)  On or about June 25, 2012 in the blow mold department, employees operating the Conair#1 re-grinder machine (hog grinder) were exposed to possibly being struck by the rotating parts at the point of operation should they unbolt and open the top barrier guard or back gate of the grinder while it is operating because the interlock was defective.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.303 G01

Serious Gravity 1 2 instances 35 exposed
Issued
Nov 6, 2012
Abate by
Nov 19, 2012
Penalty
Initial $3,300 · Current $1,650 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:        On or about June 25, 2012, October 23, 2012 and at times prior thereto in the blow mold department the failure of this employer to provide and maintain sufficient access and working space about panelboard RP-1 and a motor control center exposed employees to a delay of accessing this electrical current flow equipment should an emergency need occur.
Recent events (2)
  • — I (S) $1650
  • — Z (S) $3300

1910.22 A01

Other-than-serious 2 instances 5 exposed
Issued
Nov 6, 2012
Abate by
Nov 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.     On or about June 25, 2012 in the trimmer area of the blow mold department, two extension cords supplying power to portable fans were lying on the floor which exposed the cords to damage by being run over by forktrucks and created a possible tripping hazard to employees walking/working in the area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Warren OIL Company, INC.'s full OSHA safety record →