Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: STELRAY PLASTIC PRODUCTS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STELRAY PLASTIC PRODUCTS, INC. in 151 WAKELEE AVENUE 50 WESTFIELD AVE, ANSONIA, CT 06401 (NAICS 326199). OSHA activity number 334839586.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stelray Plastic Products, INC. for free Get an email when a new federal OSHA severe-injury report for Stelray Plastic Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
151 WAKELEE AVENUE 50 WESTFIELD AVE
City
ANSONIA
State
CT
ZIP
06401
Mailing
50 WESTFIELD AVENUE, ANSONIA, CT 06401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
39
Ownership type
A

9 citations on file for this inspection.

1910.38 C03

Serious Gravity 1 38 exposed
Issued
Nov 21, 2012
Abate by
Feb 28, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.38(c)(3):  Procedures were not in place for employees who remain to operate critical plant operations before they evacuate;    Facility: Written procedures were not in place where employees were authorized to remain to handle and control "critical issues "during an emergency prior to evacuating the facility.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.38 C04

Serious Gravity 1 39 instances 39 exposed
Issued
Nov 21, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
20 CFR 1910.38(c)(4): The emergency action plan (EAP), at a minimum, did not include procedure for accountability for all employees after evacuation.     Facility: The employer did not include an accountability procedure in their EAP.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.38 F

Serious 39 instances 39 exposed
Issued
Nov 21, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.38(f):  The employer did not review the emergency action plan (EAP) with each employee covered by the plan:    Facility:  Employer did not review the EAP with the employees.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C04 I

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 21, 2012
Abate by
Feb 28, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section    Facility: The employer did not establish and implement written step-by-step  hazardous energy control procedures that are machine specific where employees were engaged in servicing and performing maintenance on equipment, such as (but not limited to) injection molding machine plastic granulators and  sprue pickers.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.147 C07 I

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 21, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees    Facility: The employees, as authorized, affected and other types were not provided with information and training in the controlling unexpected and hazardous energy sources, lockout/tagout procedures while employees servicing and performing maintenance on equipment, such as (but not limited to) injection molding machine plastic granulators and  sprue pickers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 G02

Serious Gravity 1 32 exposed
Issued
Nov 21, 2012
Abate by
Dec 18, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting  was not provided to all employees upon initial employment, and at least annually thereafter.    Facility: The employees, expected and allowed to control incipient stage fires with portable fire extinguishers were not provided with information and basic training.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.178 L01 I

Serious Gravity 5 1 exposed
Issued
Nov 21, 2012
Abate by
Dec 18, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.178(l)(1)(i):  The employer did not ensure that each powered industrial truck (PIT) operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    Facility:  The employer did not ensure through providing appropriate information and training that the employees authorized to operate powered industrial truck (PIT) were competent enough to operate PITs safely and appropriately at all times.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.134 C02 I

Other-than-serious 4 exposed
Issued
Nov 21, 2012
Abate by
Dec 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i):  Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    Facility: The employees who were voluntarily wearing N95 white filtering face pieces  were not provided with a copy of Appendix D.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01 I

Other-than-serious 6 exposed
Issued
Nov 21, 2012
Abate by
Jan 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet.    Facility: A list of chemicals handled and used by the employees was not included in the employer's written hazard communication program.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Stelray Plastic Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334839586.