OSHA Inspection: FIREKING BAKING COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FIREKING BAKING COMPANY, INC. in 101 CAMPANELLI DRIVE, BRAINTREE, MA 02184 (NAICS 311812). OSHA activity number 334846193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fireking Baking Company, INC. — free Get an email when a new federal OSHA severe-injury report for Fireking Baking Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
101 CAMPANELLI DRIVE
City
BRAINTREE
State
MA
ZIP
02184
Mailing
101 CAMPANELLI DRIVE, BRAINTREE, MA 02184
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
56
Ownership type
A

6 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 13, 2012
Abate by
Aug 14, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.133(a)(1):     Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    (a) during the cleaning of machinery, persons, and equipment by employees.     Employees cleaned machinery, including the Rheon VX 122 V4 Divider, with compressed air without the use of safety glasses.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.147 C04 I

Serious Gravity 10 1 instance 50 exposed
Issued
Aug 13, 2012
Abate by
Sep 4, 2012
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      The company did not have a written lock out / tag out program for the Rheon VX122 V4 Divider and other machinery.  While attempting to clean the hopper, an employee's arm was caught and injured by the dough divider star cutter blades.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.147 C07 I

Serious Gravity 10 30 exposed
Issued
Aug 13, 2012
Abate by
Nov 1, 2012
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i):     The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    Employees servicing machinery, including the Rheon VX 122 V4 Divider, were not adequately trained in lock out tag out procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.212 A03 II

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 13, 2012
Abate by
Oct 1, 2012
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    The Rheon VX122 V4 Divider's points of operation were not adequately guarded:    Instance A:  dough hopper    Instance B:  guillotine
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2012
Abate by
Aug 14, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.101(b):     The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    Location:  Production Room    Employees used compressed air to clean off their clothing and persons.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.242 B

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 13, 2012
Abate by
Nov 1, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Location:  Production Room    Compressed air used to clean machinery is used at pressures well in excess of 30 psi.  The compressed air was used to clean both the Rheon divider and the Konig roll making machine.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

View Fireking Baking Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334846193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.