BRAINTREE, MA —
OSHA Inspection: FIREKING BAKING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FIREKING BAKING COMPANY, INC. in 101 CAMPANELLI DRIVE, BRAINTREE, MA 02184 (NAICS 311812). OSHA activity number 334846193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIREKING BAKING COMPANY, INC.
- Site address
- 101 CAMPANELLI DRIVE
- City
- BRAINTREE
- State
- MA
- ZIP
- 02184
- Mailing
- 101 CAMPANELLI DRIVE, BRAINTREE, MA 02184
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 56
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.133 A01
- Issued
- Aug 13, 2012
- Abate by
- Aug 14, 2012
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: (a) during the cleaning of machinery, persons, and equipment by employees. Employees cleaned machinery, including the Rheon VX 122 V4 Divider, with compressed air without the use of safety glasses.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.147 C04 I
- Issued
- Aug 13, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The company did not have a written lock out / tag out program for the Rheon VX122 V4 Divider and other machinery. While attempting to clean the hopper, an employee's arm was caught and injured by the dough divider star cutter blades.
Recent events (2)
- — I (S) $3430
- — Z (S) $4900
1910.147 C07 I
- Issued
- Aug 13, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Employees servicing machinery, including the Rheon VX 122 V4 Divider, were not adequately trained in lock out tag out procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.212 A03 II
- Issued
- Aug 13, 2012
- Abate by
- Oct 1, 2012
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): The Rheon VX122 V4 Divider's points of operation were not adequately guarded: Instance A: dough hopper Instance B: guillotine
Recent events (2)
- — I (S) $3430
- — Z (S) $4900
1910.101 B
- Issued
- Aug 13, 2012
- Abate by
- Aug 14, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Location: Production Room Employees used compressed air to clean off their clothing and persons.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.242 B
- Issued
- Aug 13, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Location: Production Room Compressed air used to clean machinery is used at pressures well in excess of 30 psi. The compressed air was used to clean both the Rheon divider and the Konig roll making machine.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
More inspections at Fireking Baking Company, INC.
View Fireking Baking Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334846193.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.