Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CLEMENTE HERRERA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLEMENTE HERRERA in 6273 RED GLARE DRIVE LOT 280, GALLOWAY, OH 43119 (NAICS 236115). OSHA activity number 334865193.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clemente Herrera for free Get an email when a new federal OSHA severe-injury report for Clemente Herrera is published. One employer, no account, unsubscribe in one click.
Establishment
CLEMENTE HERRERA
Site address
6273 RED GLARE DRIVE LOT 280
City
GALLOWAY
State
OH
ZIP
43119
Mailing
600 FRENCH DRIVE, COLUMBUS, OH 43228
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 F04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(f)(4):     Any part of a scaffold damaged or weakened such that its strength is less than that required by paragraph (a) of this section shall be immediately repaired or replaced, braced to meet those provisions, or removed from service until repaired.    a. At the site, employees were installing vinyl siding on the side of a residential home from a pump jack scaffold that had significant damage to its work platform, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • · Z (S) $1360

1926.451 G04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(g)(4)(i):     Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.    a.  At the site, employees were installing vinyl siding on a residential home from a pump jack scaffold that did not have a complete guardrail system installed on both ends of the scaffold, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • · Z (S) $1360

1926.451 G04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(g)(4)(iii):     When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they shall be installed between the top edge of the guardrail system and the scaffold platform.    a.  At the site, employees were installing vinyl siding on the side of a residential home from a pump jack scaffold that did not have mesh secured from the top edge of the guardrail system and the scaffold's platform across the entire front of the scaffold, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • · Z (S) $1360

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.452(j)(2):     Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    a.  At the site, employees were installing vinyl siding on the side of a residential home from a pump jack scaffold that was not braced at the bottom of one the scaffold's poles, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • · Z (S) $1360