MEMPHIS, MO —
OSHA Inspection: ALL-STATES EQUIPMENT INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALL-STATES EQUIPMENT INC in 635 W STRONG BLVD, MEMPHIS, MO 63555 (NAICS 332999). OSHA activity number 334872991.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL-STATES EQUIPMENT INC
- Site address
- 635 W STRONG BLVD
- City
- MEMPHIS
- State
- MO
- ZIP
- 63555
- Mailing
- RR3 BOX 166, MEMPHIS, MO 63555
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.38 C
- Issued
- Jul 24, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $900 · Current $630 Reduced
General-duty citation text
29 CFR 1910.38(c): The employer did not implement an emergency action plan which included at a minimum the elements required by paragraphs 1910.38(c)(1)-(6) of this part: (a) At the All-States Equipment facilities an emergency action plan had not been implemented in order to provide for safe evacuation and accounting of employees in the event of an evacuation type emergency. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $630
- — Z (S) $900
1910.132 D01
- Issued
- Jul 24, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: (a) At the facility PPE had been provided and required to be used in areas such as but not limited to welding and wood working. A hazard assessment had not been performed to determine if hazards were present which necessitate the use of personal protective equipmsnt. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.147 C04 I
- Issued
- Jul 24, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $900 · Current $630 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) At the facility electrical repairs and machine repairs such as welder maintenance were performed without Lock Out Tag Out program. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $630
- — Z (S) $900
1910.212 A01
- Issued
- Jul 24, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) In the woodworking shop the Serial no 51-7960 drill press was not guarded to protect employees from rotating components, cutting tools, and flying chips Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.305 B01 II
- Issued
- Jul 24, 2012
- Abate by
- Aug 23, 2012
- Penalty
- Initial $1,500 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) In the welding area on the south wall the Eaton 220 volt panel was missing breakers and had exposed openings which had not been closed to protect employees from accidental contact or potential exosure to arcing due to insect or small varmint nesting. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1050
- — Z (S) $1500
More inspections at All-States Equipment INC