OSHA Inspection: ALL-STATES EQUIPMENT INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALL-STATES EQUIPMENT INC in 635 W STRONG BLVD, MEMPHIS, MO 63555 (NAICS 332999). OSHA activity number 334872991.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch All-States Equipment INC — free Get an email when a new federal OSHA severe-injury report for All-States Equipment INC is published. One employer, no account, unsubscribe in one click.
Site address
635 W STRONG BLVD
City
MEMPHIS
State
MO
ZIP
63555
Mailing
RR3 BOX 166, MEMPHIS, MO 63555
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.38 C

Serious Gravity 1 1 instance 10 exposed
Issued
Jul 24, 2012
Abate by
Aug 23, 2012
Penalty
Initial $900 · Current $630 Reduced
29 CFR 1910.38(c):     The employer did not implement an emergency action plan which included at a minimum the elements required by paragraphs 1910.38(c)(1)-(6) of this part:     (a)     At the All-States Equipment facilities an emergency action plan had not been implemented in order to provide for           safe evacuation and accounting of employees in the event of an evacuation type emergency.        Abatement verification is required for this violation.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $630
  • — Z (S) $900

1910.132 D01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 24, 2012
Abate by
Aug 23, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.132(d)(1):     The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:    (a)     At the facility PPE had been provided and required to be used in areas such as but not limited to welding and           wood working.  A hazard assessment had not been performed to determine if hazards were present which             necessitate the use of personal protective equipmsnt.        Abatement verification is required for this violation.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.147 C04 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 24, 2012
Abate by
Aug 23, 2012
Penalty
Initial $900 · Current $630 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a)     At the facility electrical repairs and machine repairs such as welder maintenance were performed without           Lock Out Tag Out program.        Abatement verification is required for this violation.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $630
  • — Z (S) $900

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2012
Abate by
Aug 23, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a)     In the woodworking shop the Serial no 51-7960 drill press was not guarded to protect employees from             rotating components, cutting tools, and flying chips      Abatement verification is required for this violation.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 24, 2012
Abate by
Aug 23, 2012
Penalty
Initial $1,500 · Current $1,050 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a)     In the welding area on the south wall the Eaton 220 volt panel was missing breakers and had exposed openings              which had not been closed to protect employees from accidental contact or potential exosure to arcing due to           insect or small varmint nesting.       Abatement verification is required for this violation.  The abatement certification sheet is enclosed with the citation(s).