Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: H.E. NEUMANN COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of H.E. NEUMANN COMPANY in 101 EAST MAIN ST., SAINT CLAIRSVILLE, OH 43950 (NAICS 238220). OSHA activity number 334888583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H.E. Neumann Company — free Get an email when a new federal OSHA severe-injury report for H.E. Neumann Company is published. One employer, no account, unsubscribe in one click.
Site address
101 EAST MAIN ST.
City
SAINT CLAIRSVILLE
State
OH
ZIP
43950
Mailing
P.O. BOX 6208, TRIADELPHIA, WV 26059
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
65
Ownership type
A

4 citations on file for this inspection.

1926.501 B04 II

Serious Gravity 1 4 instances 10 exposed
Issued
Jul 13, 2012
Abate by
Jul 20, 2012
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1926.501(b)(4)(ii):     Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.    A. On the first floor of the building, employees were working in rooms where holes were cut into the floor for HVAC registers and not covered, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1926.502 I03

Serious Gravity 1 4 instances 10 exposed
Issued
Jul 13, 2012
Abate by
Jul 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(3):     All covers shall be secured when installed so as to prevent accidental displacement by the wind, equipment, or employees.    a. On the first floor of the building, employees were working in rooms where holes were cut into the floor for HVAC registers and covers not secured, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 I04

Serious Gravity 1 4 instances 10 exposed
Issued
Jul 13, 2012
Abate by
Jul 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4):     All covers shall be color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard.  Note: This provision does not apply to cast iron manhole covers or steel grates used on streets or roadways.    a. On the first floor of the building, employees were working in rooms where holes were cut into the floor for HVAC registers and covers not marked, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2012
Abate by
Jul 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    a. In the mechanical room on the third floor, flexible cords were being used with exposed interior wire insulation due to faulty strain relief, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View H.E. Neumann Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334888583.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.