Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: ASTRO BUILDINGS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ASTRO BUILDINGS INC. in E REICHMUTH RD & REICHMUTH CIRCLE, VALLEY, NE 68064 (NAICS 236220). OSHA activity number 334893443.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Astro Buildings INC. for free Get an email when a new federal OSHA severe-injury report for Astro Buildings INC. is published. One employer, no account, unsubscribe in one click.
Site address
E REICHMUTH RD & REICHMUTH CIRCLE
City
VALLEY
State
NE
ZIP
68064
Mailing
1109 SOUTH 19TH STREET, SUITE A, OMAHA, NE 68108
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
30
Ownership type
Private (A)

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,380 · Current $1,963 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface:    E. Reichmuth Rd & Reichmuth Circle, Valley, NE 68064 (Job-site): The employer did not ensure that ladders were available to descend from the roof to the RustCo scaffold. The scaffold platform was approximately 3 1/2 feet below the roof.    Abatement certification is required for this violation.  Abatement certification sheet is enclosed with the citation.
Recent events (2)
  • · I (S) $1963
  • · Z (S) $2380

1926.1051 A

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where  there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:                                                                                                                    E. Reichmuth Rd & Reichmuth Circle, Valley, NE 68064 (Job-site): The employer did not ensure that ladders were available to access the roof from the RustCo scaffold. The scaffold platform was approximately 3 1/2 feet below the roof.    Abatement certification is required for this violation.  Abatement certification sheet is enclosed with the citation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,380 · Current $1,964 Reduced
29 CFR 1926.1053(b)(5)(i):  Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and top support):    E. Reichmuth Rd & Reichmuth Circle, Valley, NE 68064 (Job-site): The portable ladder being used by an employee to access the scaffold was being used at an angle of approximately one-half the working length of the ladder (9 feet high and 5 feet distance between the foot and top support).    Abatement certification is required for this violation.  Abatement certification sheet is enclosed with the citation.
Recent events (2)
  • · I (S) $1964
  • · Z (S) $2380

1926.1053 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2012
Abate by
Nov 1, 2012
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1926.1053(b)(9):  The area around the top and/or bottom of (a) ladder(s) was not kept clear:    E. Reichmuth Rd & Reichmuth Circle, Valley, NE 68064 (Job-site): The portable ladder being used by an employee to access the scaffold did not clear the cross bracing at the top of the scaffold.     Abatement certification is required for this violation.  Abatement certification sheet is enclosed with the citation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2380

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334893443.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.