OSHA Inspection: REESE CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of REESE CO. in 229 PARTRIDGE LANE, HERMON, ME 04401 (NAICS 236115). OSHA activity number 334899986.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reese CO. for free Get an email when a new federal OSHA severe-injury report for Reese CO. is published. One employer, no account, unsubscribe in one click.
Establishment
REESE CO.
Site address
229 PARTRIDGE LANE
City
HERMON
State
ME
ZIP
04401
Mailing
205 BEMIS ROAD, CARMEL, ME 04419
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
1
Ownership type
Private (A)

11 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,700 · Current $780 Reduced
29 CFR 1926.304(h)(1):     Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.    Garage - The 10" DeWalt table saw did not have a hood guard.
Recent events (2)
  • · I (S) $780
  • · Z (S) $1700

1926.403 B01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.403(b)(1)(vii):     1926.403(b)(1)(vii):   Safety of equipment were not determined on the basis of the following considerations: Other factors which contribute to the practical safeguarding of employees using or likely to come in contact with the equipment:    East Side - The defective ground fault circuit interrupting receptacle did not deenergize when the test button was pressed.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $2800

1926.404 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    In the following instances, equipment did not have a permanent and continuous grounding path:    a) East of House - The blue extension cord was missing a grounding pin.    b) Garage - The electrical cord to the Heat Buster fan with a metal frame was missing a grounding pin.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.403 I02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.403(i)(2)(i):     Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:    Garage - The energized 120/240 volt Square D 100 amp main electrical service panel was inadequately closed, exposing live electrical wiring.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $2800

1926.405 G02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    Garage - The cable from the service panel used to energize the temporary power panel did not have strain relief.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 C02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.451(c)(2)(i):     Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.    South Side of House - The two Alum-A-Pole scaffold support poles did not have any footing support.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $2800

1926.451 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(3):     Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.    South Side of House - The two Alum-A-Pole support poles were not plumb.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G04 I

Serious Gravity 10 2 instances 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i):     Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.    South Side of House - The Alum-A-Pole scaffold system had an inadequate guardrail system in that the midrail and east end rail were missing.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.451(f)(6):     Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.    Southeast Corner of House - The east end of the scaffold was erected approximately 27" from the energized 120/240 volt service drop.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $2800

1926.501 B14

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2012
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.501(b)(14):     "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.    West Side of House - The 32" wall opening, measuring from 6' 10" to the ground, for the patio doorway was left unguarded.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $2800

1926.1052 C01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,360 · Current $620 Reduced
29 CFR 1926.1052(c)(1)(i):     Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    In the House - The stairway from the basement to the living room had at least 11 risers and was not equipped with at least one handrail.
Recent events (2)
  • · I (S) $620
  • · Z (S) $1360