TERRYVILLE, CT ·
OSHA Inspection: TERRYVILLE AUTO PARTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TERRYVILLE AUTO PARTS, INC. in 35 FALL MOUNTAIN ROAD, TERRYVILLE, CT 06786 (NAICS 441310). OSHA activity number 334904380.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TERRYVILLE AUTO PARTS, INC.
- Site address
- 35 FALL MOUNTAIN ROAD
- City
- TERRYVILLE
- State
- CT
- ZIP
- 06786
- Mailing
- 35 FALL MOUNTAIN ROAD, TERRYVILLE, CT 06786
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 20
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 18, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Small Parts 2nd Floor Storage - On or about 6-28-12 - Storage area was missing mid rails and toeboard above the stairway, exposing employees to fall hazard of approximately 8 feet. b) Dismantling Area - On or about 6-28-12 - Storage area approximately 8 feet above the floor was not equipped with a standard railing system, exposing employees to fall hazards.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1910.23 D01 II
- Issued
- Sep 18, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side: a) Small Parts Stairway - On or about 6-28-12 - Employees were exposed to fall hazard of 5 to 8 feet from wooden stairway that was not equipped with a standard railing system. There was no mid-rail installed on the fight of stairs to the second floor storage area.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.110 E04 III
- Issued
- Sep 18, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $1,020 · Current $510 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a) At the facility - On or about 6-28-12 - Removable LPG (liquefied petroleum gas) fuel cylinder mounted on the back of the Toyota Fork Lift did not have the cylinder properly installed on the safety pin which would stop the cylinder from rotating while the fork lift was in operation.
Recent events (2)
- · I (S) $510
- · Z (S) $1020
1910.178 L01 II
- Issued
- Sep 18, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. a) At the faciltiy - On or about 6-28-12 - Employees were allowed to operate industrial fork lifts without being evaluated or trained by the employer. Employees were operating Toyota and Clark fork trucks.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1910.22 D01
- Issued
- Sep 18, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. a) Small Parts, 2nd floor Storage Area and Dismantling Storage Area - On or about 6-28-12 - Employees were exposed to struck-by hazards from storage area floors that were not provided with load plates. Floors could be overloaded and collaspe.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Terryville Auto Parts, INC.
View Terryville Auto Parts, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441310)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334904380.