Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TERRYVILLE AUTO PARTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TERRYVILLE AUTO PARTS, INC. in 35 FALL MOUNTAIN ROAD, TERRYVILLE, CT 06786 (NAICS 441310). OSHA activity number 334904380.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Terryville Auto Parts, INC. for free Get an email when a new federal OSHA severe-injury report for Terryville Auto Parts, INC. is published. One employer, no account, unsubscribe in one click.
Site address
35 FALL MOUNTAIN ROAD
City
TERRYVILLE
State
CT
ZIP
06786
Mailing
35 FALL MOUNTAIN ROAD, TERRYVILLE, CT 06786
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
20
Ownership type
Private (A)

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 18, 2012
Abate by
Oct 18, 2012
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    a) Small Parts 2nd Floor Storage - On or about 6-28-12 - Storage area was missing mid rails and toeboard above the stairway, exposing employees to fall hazard of approximately 8 feet.    b) Dismantling Area - On or about 6-28-12 - Storage area approximately 8 feet above the floor was not equipped with a standard railing system, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $680
  • · Z (S) $1360

1910.23 D01 II

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 18, 2012
Abate by
Oct 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(ii):     Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side:    a)  Small Parts Stairway - On or about 6-28-12 - Employees were exposed to fall hazard of 5 to 8 feet from wooden stairway that was not equipped with a standard railing system.  There was no mid-rail installed on the fight of stairs to the second floor storage area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.110 E04 III

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 18, 2012
Abate by
Oct 18, 2012
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.110(e)(4)(iii):     Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:    a) At the facility - On or about 6-28-12 - Removable LPG (liquefied petroleum gas) fuel cylinder mounted on the back of the Toyota Fork Lift did not have the cylinder properly installed on the safety pin which would stop the cylinder from rotating while the fork lift was in operation.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1910.178 L01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 18, 2012
Abate by
Oct 18, 2012
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.178(l)(1)(ii):   The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck.    a)  At the faciltiy - On or about 6-28-12 - Employees were allowed to operate industrial fork lifts without being evaluated or trained by the employer.  Employees were operating Toyota and Clark fork trucks.
Recent events (2)
  • · I (S) $680
  • · Z (S) $1360

1910.22 D01

Other-than-serious 2 instances 2 exposed
Issued
Sep 18, 2012
Abate by
Oct 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):   On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    a)  Small Parts, 2nd floor Storage Area and Dismantling Storage Area - On or about 6-28-12 - Employees were exposed to struck-by hazards from storage area floors that were not provided with load plates.  Floors could be overloaded and collaspe.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Terryville Auto Parts, INC.'s full OSHA safety record →