WASHINGTON, DC —
OSHA Inspection: D.A. FOSTER
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of D.A. FOSTER in 1120 RHODE ISLAND AVE, WASHINGTON, DC 20010 (NAICS 221210). OSHA activity number 334911989.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D.A. FOSTER
- Site address
- 1120 RHODE ISLAND AVE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 23560 PEBBLE RUN PL, STERLING, VA 20166
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221210
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 13, 2012
- Abate by
- Jan 2, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that the machine or equipment is isolated from the energy source and rendered inoperative before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury. a) On or about June 15, 2012; at the northside of home; the employer had not developed a specific energy control plan that outlines each step that must be taken while replacing or relocating low pressure gas lines ensuring natural gas is controlled from unexpected energizing/ignition.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.147 C05 I
- Issued
- Dec 13, 2012
- Abate by
- Jan 2, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware was not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources. a) On or about June 15, 2012; northside of home; the employer had not provided proper isolating equipment such as but not limited to low pressure plugs to be used during the installation/relocation of gas meters.
Recent events (2)
- — I (O) $4900
- — Z (S) $4900
More inspections at D.A. Foster