DURAND, WI —
OSHA Inspection: COUNTRYSIDE COOPERATIVE INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COUNTRYSIDE COOPERATIVE INC in 514 EAST MAIN STREET, DURAND, WI 54736 (NAICS 424510). OSHA activity number 334915386.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COUNTRYSIDE COOPERATIVE INC
- Site address
- 514 EAST MAIN STREET
- City
- DURAND
- State
- WI
- ZIP
- 54736
- Mailing
- 514 EAST MAIN STREET, DURAND, WI 54736
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 30
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.23 A02
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: (a) Countryside Cooperative, Grain Bin Area; Work platforms were not protected with a standard guard rail system for fall protection on equipment, such as, but not limited to: (1) The Fines and Wet Bins on the East side of the dryer; The work platform guard rail system did not have an intermediate railing, and (2) The Fines Bin on the West side of the dryer; The work platform did not have a guard rail system in place.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.27 D01 IV
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(d)(1)(iv): Cages on fixed ladders did not extend down the ladder to a point not less than 7 feet nor more than 8 feet above the base of the ladder, with bottom flared not less than 4 inches, or portion of cage opposite ladder shall be carried to the base: (a) Countryside Cooperative, Grain Bin Area; The protective ladder cages did not start between seven and eight feet from the base of the ladder on equipment, such as, but not limited to: (1) The Soy Bean Leg; The ladder cage started at 11 feet 4 inches above the base, and (2) Grain Bin Number 1; The ladder cage started at 11 feet 1 inch above the base.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 II B
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size: (a) Countryside Cooperative, Throughout the Facility; Lockout devices were not standardized.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.147 D03
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Countryside Cooperative, Throughout the Facility; Lockout was performed on circuitry controls in a manner that did not physically isolate the machinery from the energy source, such as but not limited to: (1) Grain Plant; The circuitry controls panel on the South side of the Scale Room, and (2) Feed Mill, The circuitry control station located outside of the office.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 II D
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) Countryside Cooperative, Feed Mill; Each employee performing group maintenance or servicing on grain streaming equipment did not affix their own lock to isolate the energy source.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A02
- Issued
- Sep 28, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) Countryside Cooperative, Grain Bin Number 11; The machine guard covering the belt and pulley for the discharge auger was not secured and easily bypassed.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.219 D01
- Issued
- Sep 28, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Countryside Cooperative, Grain Bin Number 3; The machine guarding for the discharge auger drive did not fully enclose the belt and pulley drive system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E01 I
- Issued
- Sep 28, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Countryside Cooperative, Grain Bin Number 3; The machine guarding for the discharge auger did not fully enclose the belt and pulley drive system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) Countryside Cooperative, Grain Bin Number 9; Employees were exposed to electrical hazards due to conduits that were broken exposing the conductors.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.303 B02
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Countryside Cooperative, Feed Mill Bagging Area; A flexible extension cord had the plug-in removed and was connected into an electrical fan motor using a romex type wire clip.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Countryside Cooperative, Grain Plant; Three electrical boxes in the Corn Electrical Shed were missing knockouts and had duct tape covering the openings.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.305 G01 IV A
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Countryside Cooperative, Feed Mill: A black extension cord was used as a substitute for fixed wiring in the feed bagging area, where it was draped and wrapped around the building structure and being used to power a portable fan.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- Sep 28, 2012
- Abate by
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: (a) Countryside Cooperative, Maintenance Building; Safe load capacities were not clearly marked on the overhead storage level above the administrative offices, bathrooms and break area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Countryside Cooperative INC
View Countryside Cooperative INC's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334915386.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.