Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: COMPUTECH MANUFACTURING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMPUTECH MANUFACTURING COMPANY, INC. in 1701 IRON STREET, NORTH KANSAS CITY, MO 64116 (NAICS 336413). OSHA activity number 334920782.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Computech Manufacturing Company, INC. for free Get an email when a new federal OSHA severe-injury report for Computech Manufacturing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1701 IRON STREET
City
NORTH KANSAS CITY
State
MO
ZIP
64116
Mailing
1701 IRON STREET, NORTH KANSAS CITY, MO 64116
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
46
Ownership type
Private (A)

10 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) An employee was required to use a 1/2 faced 3M 6200 fitted respirator when painting and the employee had not received a medical evaluation prior to being fit tested or required to use the respirator in the workplace.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.134 F

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f): The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used:    (a) Painters were required to use a 1/2 faced 3M 6200 respirator without being fit tested with the same make, model, style and size of respirator that was to be used.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 P01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    (a) The Caterpillar 40 D forklift did not have a nonslip cover on the left brake pedal and had not been taken out of service.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.215 B09

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 27, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) The Sunex Tools Bench Grinder in the Fabrication Area was adjusted at greater than one fourth inch on both wheels.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $3,570 · Current $2,499 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) Pulleys, such as, but not limited to, the pulleys for the Bridgeport Milling Machine, in the Unison Bend Area, were not guarded within seven feet of the ground. Belt and pulleys created an ingoing nippoint which was not guarded.
Recent events (2)
  • · I (S) $2499
  • · Z (S) $3570

1910.219 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $0 · Current $0
1910.219(e)(1):  Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard did not extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this section.    (a) The horizontal belt, such as, but not limited to the belt for the Bridgeport Milling Machine, in the Unison Bend Area, was not guarded within seven feet of the ground.  The belt and pulleys created an ingoing nippoint which was not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Air nozzles, such as, but not limited to, the air nozzle in the Cold Saw/Back Shell Area used for cleaning measured at 100 p.s.i.    (b) An air nozzle, used for cleaning in the East Side Machine Shop by the Mori Seiki- C1200 Lathe measured at 60 p.s.i.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.303 B02

Serious Gravity 5 20 instances 30 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Electrical boxes with knockouts were used with flexible cord, such as, but not limited to, the four plex electrical box, in the Back Shell Area, was used with flexible cord which was not used or installed per instructions included in the listing or labelling.  Electrical boxes with knockouts are listed or labelled to be used with rigid conduit and mounted to a wall or piece of equipment.    (b) An electrical two plex electrical box in the Back Shell Area to operate the Optical Comparator and a fan was not used or installed per instructions included in the listing or labelling. The two plex electrical box was used with flexible cord as an extension cord and the electrical box is listed or labelled to be used with rigid conduit and mounted to a wall or piece of equipment.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.305 B01 II

Serious Gravity 1 1 instance 12 exposed
Issued
Jul 27, 2012
Abate by
Aug 26, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) There was an open knockout in the GE Northeast 110 electrical box in the Saw Area that was not closed.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) There was not adequate strain relief to the Dayton 24 inch circular fan in the Weld Area as next to the fan motor there was not adequate strain relief as the outer insulation had pulled back exposing interior wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Computech Manufacturing Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334920782.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.