WASHINGTON, DC —
OSHA Inspection: AJG INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of AJG INC. in 3036 MACOMB STREET NW, WASHINGTON, DC 20008 (NAICS 238130). OSHA activity number 334931789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AJG INC.
- Site address
- 3036 MACOMB STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20008
- Mailing
- 5703 COURTNEY DRIVE, LOTHIAN, MD 20711
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.502 I04
- Issued
- Nov 13, 2012
- Penalty
- Initial $2,200 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.502(i)(4): All covers shall be color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard. a) 1st Floor Deck, Elevator Shaft Floor Hole - A plywood cover used to cover a 5 foot x 5 foot floor hole had not been marked with the words "Hole" or "Cover" or color coded to provide warning of the hazard, on or about 06/29/12. b) 1st Floor Deck, Chimney Floor Hole - A plywood cover used to cover a 3 foot x 2 foot floor hole had not been marked with the words "Hole" or "Cover" or color coded to provide warning of the hazard, on or about 06/29/12. c) 1st Floor Deck, L-shaped Stairway Floor Hole - A plywood cover used to cover a floor hole 4 foot x 6 foot (east to west) and 3 foot - 1 inch x 6 foot -5 inch (north to south) had not been marked with the words "Hole" or "Cover" or color coded to provide warning of the hazard, on or about 06/29/12.
Recent events (2)
- — I (S) $1100
- — Z (S) $2200
1926.501 B13
- Issued
- Nov 13, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $15,400 · Current $7,700 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) of this section: a) First Floor Deck - A carpenter working at an L-shaped floor hole (6 feet - 5 inches x 3 feet - 1 inch short side and 4 feet x 6 feet long side) was not protected from a 10 foot - 6 inch fall hazard, on or about May 22, 2012. AJG Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 315679332, citation number 1, item number 1 and was affirmed as a final order on August 2, 2011, with respect to a workplace located at 4400 Reno Road, NW, Washington, DC 20015 ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (R) $7700
- — Z (R) $15400
1904.39 A
- Issued
- Nov 13, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $5,500 · Current $2,750 Reduced
General-duty citation text
29 CFR 1904.39(a): The employer did not orally report the death of an employee because of a work-related incident located at 3036 Macomb Street NW, Washington, DC 20008. a) AJG Inc. - The employer failed to report to OSHA within eight (8) hours a work-related death, on or about May 22, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $2750
- — Z (O) $5500
1926.503 B01
- Issued
- Nov 13, 2012
- Abate by
- Dec 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) Job Site - A written certification record of fall protection training given to each employee exposed to fall hazards was not provided, on or about 06/29/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238130)