Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: SILVER STAR HOME IMPROVEMENTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SILVER STAR HOME IMPROVEMENTS in 237 SMITH STREET, MERRICK, NY 11566 (NAICS 236115). OSHA activity number 334940988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Silver Star Home Improvements — free Get an email when a new federal OSHA severe-injury report for Silver Star Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
237 SMITH STREET
City
MERRICK
State
NY
ZIP
11566
Mailing
3274 MARTHA BLVD., BETHPAGE, NY 11714
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
11
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2012
Penalty
Initial $2,800 · Current $1,300 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) Worksite - An employee working directly under roof work, where employees were using tools, did not have head protection; on or about 06/28/12.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 7, 2012
Penalty
Initial $2,800 · Current $1,300 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) Worksite - Employees were working, at a height of approximately 28 feet above the ground, on an approximately 14-12 pitch residential roof without fall protection; on or about 06/28/12.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2800

1926.951 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2012
Penalty
Initial $2,800 · Current $1,300 Reduced
29 CFR 1926.951(c)(1): Portable conductive ladder(s) were used near energized lines or equipment:    a) worksite - Employees were using a metal ladder to gain access to the roof that was approximately 3 inches away from the approximately 220 volts house service line, on or about 06/28/12.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 7, 2012
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a)Worksite - Employees were using a ladder to gain access to a roof. The ladder was not secured and the side rails extended approximately 18 inches above the upper landing; on or about 06/28/12.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334940988.