MEADVILLE, PA —
OSHA Inspection: FISKE ASSOCIATES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FISKE ASSOCIATES, INC. in 894 DIAMOND PARK, MEADVILLE, PA 16335 (NAICS 238990). OSHA activity number 334944980.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FISKE ASSOCIATES, INC.
- Site address
- 894 DIAMOND PARK
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 10651 LAKE PLEASANT RD., WATERFORD, PA 16441
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 18, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace [As adopted by reference in 29 CFR 1926.103]: a) construction site at 894 Diamond Park in Meadville, PA. On or about June 28, 2012, employees were not medically evaluated to determine if they could wear the 3M 8210Plus Particulate Respirator. The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.134 F02
- Issued
- Jul 18, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter [As adopted by reference in 29 CFR 1926.103]: a) construction site at 894 Diamond Park in Meadville, PA. On or about June 28, 2012, employees using the 3M 8210Plus Particulate Respirator were not fit-tested. The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K03
- Issued
- Jul 18, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace [As adopted by reference in 29 CFR 1926.103]: a) construction site at 894 Diamond Park in Meadville, PA. On or about June 28, 2012, employees using the 3M 8210Plus Particulate Respirator did not receive effective training on the 29 CFR 1910.134 (Respirator Standard) and on the selection, use, and maintenance of respirators. The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C
- Issued
- Jul 18, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (Construction Reference 1926.103) a) construction site at 894 Diamond Park in Meadville, PA. On or about June 28, 2012, a written respirator program was not developed. Personnel were using the 3M 8210 Plus Particulate Respirator during grinding operations to remove old mortar.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.416 E01
- Issued
- Jul 18, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) construction site at 894 Diamond Park in Meadville, PA. On or about June 28, 2012, the electrical extension cord, used to supply power to the hand held grinder, was damaged.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fiske Associates, INC.
View Fiske Associates, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334944980.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.