Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FISKE ASSOCIATES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FISKE ASSOCIATES, INC. in 894 DIAMOND PARK, MEADVILLE, PA 16335 (NAICS 238990). OSHA activity number 334944980.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiske Associates, INC. — free Get an email when a new federal OSHA severe-injury report for Fiske Associates, INC. is published. One employer, no account, unsubscribe in one click.
Site address
894 DIAMOND PARK
City
MEADVILLE
State
PA
ZIP
16335
Mailing
10651 LAKE PLEASANT RD., WATERFORD, PA 16441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace [As adopted by reference in 29 CFR 1926.103]:    a)  construction site at 894 Diamond Park in Meadville, PA.  On or about June 28, 2012, employees were not medically evaluated to determine if they could wear the 3M 8210Plus Particulate Respirator.  The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):     The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter [As adopted by reference in 29 CFR 1926.103]:    a)  construction site at 894 Diamond Park in Meadville, PA.  On or about June 28, 2012, employees using the 3M 8210Plus Particulate Respirator were not fit-tested.  The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3):     Training was not provided prior to requiring employees to use a respirator in the workplace [As adopted by reference in 29 CFR 1926.103]:    a)  construction site at 894 Diamond Park in Meadville, PA.  On or about June 28, 2012, employees using the 3M 8210Plus Particulate Respirator did not receive effective training on the 29 CFR 1910.134 (Respirator Standard) and on the selection, use, and maintenance of respirators.  The employer required use of the respirators during grinding operations to remove old mortar.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c):     The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (Construction Reference 1926.103)    a)  construction site at 894 Diamond Park in Meadville, PA.  On or about June 28, 2012, a written respirator program was not developed. Personnel were using the 3M 8210 Plus Particulate Respirator during grinding operations to remove old mortar.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 E01

Other-than-serious 2 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables were used:    a)  construction site at 894 Diamond Park in Meadville, PA.  On or about June 28, 2012, the electrical extension cord, used to supply power to the hand held grinder, was damaged.